* Configuration issues will now be reported at startup
* `[bed_mesh]`, `[probe]` and `[fan]` sections are now optional
* `[pause_resume]` section no longer needs to be set explicitly
Add support for performing Python gc work only from the main reactor
thread and only when it appears the main thread is idle.
Signed-off-by: Kevin O'Connor <kevin@koconnor.net>
Explicitly run the python garbage collector on a restart. This cleans
up memory from the previous session.
Signed-off-by: Kevin O'Connor <kevin@koconnor.net>
Make sure to terminate any greenlets that are in a pause() state.
This is necessary to ensure the reactor can be deallocated.
Signed-off-by: Kevin O'Connor <kevin@koconnor.net>
The existence of a __del__() method prevents deallocation on python2
if there are circular references. Replace the __del__() method with a
new finalize() call and arrange for it to be called when the main
reactor is released.
Signed-off-by: Kevin O'Connor <kevin@koconnor.net>
The existence of a __del__() method prevents deallocation on python2
if there are circular references. Just remove the method as
disconnect() should already be called directly.
Signed-off-by: Kevin O'Connor <kevin@koconnor.net>
The existence of a __del__() method prevents deallocation on python2
if there are circular references. Just remove the method as
disconnect() should already be called directly.
Signed-off-by: Kevin O'Connor <kevin@koconnor.net>
The default on X86 32bit machines is to use 80bit floating point math
(as found in the ancient "387 coprocessor"). This can cause numerical
stability problems. Set the compiler flags to make sure the newer SSE
math is always used on X86.
Signed-off-by: Kevin O'Connor <kevin@koconnor.net>
Add get_status wrapper with last_query status for macros It is sometimes useful to determine the state of the probe from a macro. If the probe is connected to an endstop pin, the results can be obtained via QUERY_ENDSTOPS but if a physical endstop is in use in addition to the probe the probe state cannot be obtained. This change allows one to use QUERY_PROBE and then access the printer.probe.last_query object to obtain the state.
Signed-off-by: Paul McGowan <mental405@gmail.com>
Some mcu implementations don't like it when the pwm pin is configured
twice, so use the normal schedule_pwm_out implementation to update on
a restart.
Signed-off-by: Kevin O'Connor <kevin@koconnor.net>
Try to invoke a shutdown on an unhandled exception from reactor.run().
If that fails, try to do a clean exit.
Signed-off-by: Kevin O'Connor <kevin@koconnor.net>
Update callers to use the printer.command_error reference instead of
directly using homing.CommandError() when raising or catching errors.
Signed-off-by: Kevin O'Connor <kevin@koconnor.net>
There's no reason to distinguish between an EndstopError and a
CommandError, so just use CommandError.
Signed-off-by: Kevin O'Connor <kevin@koconnor.net>