Move the quad_gantry_level description closer to z_tilt section. Move
the force_move section closer to the homing_override section.
Signed-off-by: Kevin O'Connor <kevin@koconnor.net>
Add a command that will turn off all heaters in the printer. Run this
command in the default idle_timeout action.
Signed-off-by: Kevin O'Connor <kevin@koconnor.net>
Add initial support for commands that will forcibly move a stepper
(without updating the kinematic classes with the new position).
Signed-off-by: Kevin O'Connor <kevin@koconnor.net>
Move the "motor_off_timeout" tracking to a new module in the extras/
directory. This makes it easier to customize the idle timeout
behavior.
Signed-off-by: Kevin O'Connor <kevin@koconnor.net>
It's rare to have all the Z stepper locations directly under the
printable surface, so using z_positions for points is not a good
default.
Signed-off-by: Kevin O'Connor <kevin@koconnor.net>
It appears the st7920 requires a longer delay when switching from
command to data mode (and vice-versa). Slower MCUs don't show a
problem because the klipper command processing time results in a
sufficient delay. However, some of the faster MCUs can process
klipper commands fast enough that the next st7920 transfer is sent too
fast. Add an additional delay to account for this.
Signed-off-by: Kevin O'Connor <kevin@koconnor.net>
Added a config parameter to define the homing override axes. This way
one can still home x and y axis without the z-probe cycle coming in the
way.
Signed-off-by: Hans Raaf <hr-klipper@oderwat.de>
Signed-off-by: Kevin O'Connor <kevin@koconnor.net>
Add the ability to add a custom g-code command that in turn executes
one or more configured g-code commands.
Signed-off-by: Kevin O'Connor <kevin@koconnor.net>
The recommended TOFF time in "standalone mode" according to the
tmc2130 is 4, so use that as the default.
Signed-off-by: Kevin O'Connor <kevin@koconnor.net>
If the fan's max power is limited by the config, then scale speed
requests between 0 and max_power. This makes more sense for typical
g-code fan speeds.
Signed-off-by: Kevin O'Connor <kevin@koconnor.net>
Move the probe_z_offset parameter from delta_calibrate and
bed_tilt_calibrate to a z_offset parameter within the probe config
section. It's easier to understand the z offset setting when it is in
the probe config section.
Signed-off-by: Kevin O'Connor <kevin@koconnor.net>
Rename the digital_output, pwm_output, and static_pwm_output config
sections to output_pin and move to a new module in the extras/
directory.
Signed-off-by: Kevin O'Connor <kevin@koconnor.net>
If a heater falls out of the target range, accumulate the temperature
differences to determine if an error should be raised. This should
make it less likely to report an error for heaters that drift slightly
out of range, and it should make error reporting faster for heaters
that rapidly fall out of range.
Signed-off-by: Kevin O'Connor <kevin@koconnor.net>
A default of 4 degrees and 10 seconds may be too aggressive - change
the default to 10 degrees and 15 seconds.
Signed-off-by: Kevin O'Connor <kevin@koconnor.net>
Add support for additional carriages on cartesian printers. This is
used by some printers to handle multiple extruders.
Signed-off-by: Kevin O'Connor <kevin@koconnor.net>