Commit Graph

73 Commits

Author SHA1 Message Date
Kevin O'Connor c197fdb03d heater: Fix misspelling of Celsius
Signed-off-by: Kevin O'Connor <kevin@koconnor.net>
2020-02-27 11:31:51 -05:00
FanDjango cb042e749d
homing_heaters: Turn off heaters during homing/probing (#2486)
Signed-off-by: Mike Stiemke <fandjango@gmx.de>
2020-02-12 10:08:30 -05:00
Arksine 2159f398ea heater: add support for BME280
Signed-off-by:  Eric Callahan <arksine.code@gmail.com>
2020-01-13 22:29:50 -05:00
Kevin O'Connor 4b6a65c1e0 heater: Do not flush look-ahead queue on a heater temperature update
The print_time parameter of heater.set_temp() is not currently used
and it isn't necessary to flush the look-ahead queue just get the
print_time.  Remove the parameter from heater.set_temp() to avoid
flushing the look-ahead queue.

Signed-off-by: Kevin O'Connor <kevin@koconnor.net>
2020-01-03 18:13:57 -05:00
Kevin O'Connor 665323eb29 heater: Use printer.command_error() instead of internal heater.error()
Use the more standard command_error to report invalid temperature
requests.

Signed-off-by: Kevin O'Connor <kevin@koconnor.net>
2019-12-16 19:16:58 -05:00
Simon Kühling 2721211456 heater: Add PrinterHeater get_status() function
Provide a list of available heater and sensor names to
gcode macro templates through the printer.heater.available_heaters
and printer.heater.available_sensors variables

Signed-off-by: Simon Kühling <mail@simonkuehling.de>
2019-12-13 10:45:04 -05:00
Kevin O'Connor ed610a6600 extruder: Consistently use "extruder" for the primary extruder
No longer allow the primary extruder to be named "extruder0".  This
avoids internal and external confusion between the printer objects and
config section names.

Signed-off-by: Kevin O'Connor <kevin@koconnor.net>
2019-11-07 16:28:47 -05:00
Kevin O'Connor b934313c3d heater: Wrap code to 80 columns
Signed-off-by: Kevin O'Connor <kevin@koconnor.net>
2019-02-27 13:09:24 -05:00
Douglas Hammond 3887ad4fce heater: Support generic gcode_id registration for sensors
Support reading a "gcode_id" parameter from heater/sensor config
sections.

Signed-off-by: Douglas Hammond <wizhippo@gmail.com>
Signed-off-by: Kevin O'Connor <kevin@koconnor.net>
2019-02-26 12:07:00 -05:00
Kevin O'Connor adf6040e9e gcode: Use an event to handle restart request actions
Instead of directly turning off motors, heaters, and fans from
gcode.py, raise a new event and allow the heater, fan, and toolhead to
handle the event as needed.

Signed-off-by: Kevin O'Connor <kevin@koconnor.net>
2019-02-25 21:26:27 -05:00
Kevin O'Connor c54c81dc2a heater: Return heaters with a gcode_id from new get_gcode_sensors()
The gcode.py code should not peek into the heater classes to obtain
the gcode_id.  Instead, introduce a new get_gcode_sensors() so that
the gcode.py code does not need to.

Signed-off-by: Kevin O'Connor <kevin@koconnor.net>
2019-02-25 20:34:26 -05:00
Kevin O'Connor bb4fab5570 heater: Rename add_sensor() to add_sensor_factory()
Signed-off-by: Douglas Hammond <wizhippo@gmail.com>
Signed-off-by: Kevin O'Connor <kevin@koconnor.net>
2019-02-25 20:34:12 -05:00
Kevin O'Connor cf6c5e6f18 gcode: A set temperature request should use the heater name, not the gcode id
When setting a temperature, lookup the heater via
self.heaters.lookup_heater() and do not use the gcode ids.  This fixes
temperature setting when multiple extruders share the same heater.

Signed-off-by: Kevin O'Connor <kevin@koconnor.net>
2019-02-25 20:32:30 -05:00
John Jardine 6316b2c1b6 Generic Heater Support
Adds the ability to register a custom/generic heater through a new extra called heater_generic.
This takes a gcode_id that is reported by M105. Adds a new command to set the temperature for any heater using the syntax:
SET_HEATER_TEMPERATURE HEATER=<heater_name> TARGET=<target_temp>

Signed-off-by: John Jardine <john@gprime.net>
2019-02-14 01:15:11 +00:00
john-- f6c9150349 heater: take a gcode_id when setting up a heater (#1028)
Allow an arbitrary gcode_id to be supplied during heater setup. This allows future extras to register additional IDs beyond B, and T#.

Signed-off-by: John Jardine <john@gprime.net>
2019-01-02 17:44:02 -05:00
Kevin O'Connor 174754299a heater: Add new TURN_OFF_HEATERS command
Add a command that will turn off all heaters in the printer.  Run this
command in the default idle_timeout action.

Signed-off-by: Kevin O'Connor <kevin@koconnor.net>
2018-09-18 16:01:07 -04:00
Kevin O'Connor eba252d3fd thermocouple: Add initial support for common SPI temperature sensing chips
Signed-off-by: Petri Honkala <cruwaller@gmail.com>
Signed-off-by: Kevin O'Connor <kevin@koconnor.net>
2018-07-24 11:16:05 -04:00
Kevin O'Connor 7d897d84d7 klippy: No need to pass printer reference to add_printer_objects()
The config reference already stores a reference to the printer object.

Signed-off-by: Kevin O'Connor <kevin@koconnor.net>
2018-07-12 22:26:32 -04:00
Kevin O'Connor b0ee323e2e heater: Introduce smooth_time config option; remove pid_deriv_time
Add generic temperature smoothing to the Heater class.  This is useful
to avoid min_extrude_temp and verify_heater errors due to measurement
noise.

Rename the pid_deriv_time config option to smooth_time so that the
smoothing amount need only be specified once.

Signed-off-by: Kevin O'Connor <kevin@koconnor.net>
2018-07-06 13:47:10 -04:00
Kevin O'Connor 4889e8241d pid_calibrate: Update the heater's target temperature during calibration
Update the target temperature during the pid calibration.  This gives
additional feedback to the user and it makes it less likely that a
verify_heater error will be raised during calibration.

Signed-off-by: Kevin O'Connor <kevin@koconnor.net>
2018-06-27 14:39:20 -04:00
Kevin O'Connor 7e497af184 heater: Don't peak into Heater class member variables
The control classes should not peak into the heater member variables.

Signed-off-by: Kevin O'Connor <kevin@koconnor.net>
2018-06-27 14:32:10 -04:00
Michael Barbour bf3c41cd06 temperature_fan: Add support for temperature-triggered fan.
Signed-off-by: Michael Barbour <barbour.michael.0@gmail.com>
2018-05-10 19:32:23 -04:00
Kevin O'Connor 06d73207e7 heater: Move Thermistor and Linear to their own files in extras/
Move the Thermistor code to a new thermistor.py module.  Move the
Linear code to a new adc_temperature.py module.  This simplifies the
heater.py code.

Signed-off-by: Kevin O'Connor <kevin@koconnor.net>
2018-04-04 23:14:55 -04:00
Kevin O'Connor 0fc4f0946e heater: Move adc logic into Thermistor class
The Thermistor (and Linear) class should handle all the details of
reading the ADC values and converting them to temperatures.  So, move
that logic out of the Heater() class.

Signed-off-by: Kevin O'Connor <kevin@koconnor.net>
2018-04-04 23:14:33 -04:00
Kevin O'Connor 7e78b2665e heater: Merge ThermistorBeta class into Thermistor class
Signed-off-by: Kevin O'Connor <kevin@koconnor.net>
2018-04-04 23:13:55 -04:00
Kevin O'Connor aed958eb5c heater: Add PrinterHeaters class that stores all sensors and heaters
Add a PrinterHeaters class that can stores references to available
temperature sensors and stores references to instantiated heaters.

Add a extras/heater_bed.py file and delay instantiation of the
heater_bed object.  This allows the heater.py module to be imported
earlier during the setup phase, and allows the PrinterHeaters class to
be available for registering sensors and heaters.

Signed-off-by: Kevin O'Connor <kevin@koconnor.net>
2018-04-04 23:13:53 -04:00
Kevin O'Connor 4eeb43b191 pins: Remove module level get_printer_pins() and setup_pin() functions
Most callers did a lookup of the pins module via
printer.lookup_object("pins").  Use that as the standard method and
remove these less frequently used methods.

Signed-off-by: Kevin O'Connor <kevin@koconnor.net>
2018-04-04 12:26:39 -04:00
Kevin O'Connor b0b4bc8958 heater: Add some comments to the thermistor math
Signed-off-by: Kevin O'Connor <kevin@koconnor.net>
2018-03-29 16:40:26 -04:00
Kevin O'Connor 973ef97143 pid_calibrate: Move PID calibration logic from heater.py to new file
Drop support for M303 and PID_TUNE, and replace it with a new
PID_CALIBRATE command.  Move the logic for this command from heater.py
to a new pid_calibrate.py file in the extras/ directory.

Signed-off-by: Kevin O'Connor <kevin@koconnor.net>
2018-03-18 12:02:30 -04:00
Kevin O'Connor e336c24665 heater: Allow min_temp to go below zero
Signed-off-by: Kevin O'Connor <kevin@koconnor.net>
2018-03-12 14:36:45 -04:00
Kevin O'Connor 5208fc38ed verify_heater: Add initial support for verifying heaters and sensors
Add runtime checks to heaters and temperature sensors to check for
possible hardware faults.

Signed-off-by: Kevin O'Connor <kevin@koconnor.net>
2018-03-11 00:49:11 -05:00
Kevin O'Connor 08a5f8a5ff display: Add initial support for LCD screens attached to an MCU
Add support for displaying basic status information on ST7920 and
HD44780 based LCDs that are attached directly to a micro-controller.

Signed-off-by: Marcio Teixeira <marcio@alephobjects.com>
Signed-off-by: Kevin O'Connor <kevin@koconnor.net>
2018-03-06 11:30:46 -05:00
Kevin O'Connor e0cedfb853 heater: Report stats whenever the heater is active
Signed-off-by: Kevin O'Connor <kevin@koconnor.net>
2018-02-05 13:55:59 -05:00
Kevin O'Connor 0a5b07f9da klippy: Allow any stats producer to determine when stats are needed
Instead of using the toolhead class to determine if stats should be
reported, allow every printer object with a stats() callback to
determine if stats are needed.

Signed-off-by: Kevin O'Connor <kevin@koconnor.net>
2018-02-05 13:52:05 -05:00
Kevin O'Connor 6eefbe5e30 heater: Add stats reporting
Report the current temperature, current pwm setting, and target
temperature as statistics in the log.

Signed-off-by: Kevin O'Connor <kevin@koconnor.net>
2018-01-28 23:37:56 -05:00
Kevin O'Connor 81013ba5c8 klippy: Add access methods and avoid peeking into the printer classes
Add get_reactor(), lookup_object(), lookup_module_objects(), and
set_rollover_info() to the main Printer class so that callers do not
need to peek into the class' members.  Similarly, add get_printer()
and get_name() methods to the ConfigWrapper class.

Signed-off-by: Kevin O'Connor <kevin@koconnor.net>
2018-01-28 12:19:26 -05:00
Kevin O'Connor 5caff594c5 heater: Report PID tuning results via the g-code terminal
Determine the median period from the pin tuning tests and use that to
recommend a set of PID parameters.  Report the results over the g-code
terminal.

Signed-off-by: Kevin O'Connor <kevin@koconnor.net>
2018-01-10 22:58:12 -05:00
Andy Silverman b22a81cd34 heater: Added config for heater PWM cycle time.
Added the pwm_cycle_time option for heater config sections.  Defaults
to previous value of 0.100 seconds, but may be reduced to shorter times
at the expense of MCU workload and possible MOSFET heating, depending on
controller design.  Some printers that need bed PID to be enabled,
notably the Felixprinters series, are known to benefit from shorter
cycle times, as the default 10hz rate results in excessive voltage
supply droop.

While this option can be used on extruder heaters as well, there
is not expected to be any particular benefit from doing so unless
the extruder heater presents a particularly large load.

Signed-off-by: Andy Silverman <andrewsi@outlook.com>
Signed-off-by: Kevin O'Connor <kevin@koconnor.net>
2018-01-03 12:32:11 -05:00
Kevin O'Connor bba22ab7f0 heater: Provide symbolic names for pid check_busy (aka M109 / M190)
Add PID_SETTLE_DELTA and PID_SETTLE_SLOPE constants to the code to try
and make it a little more clear how the wait for temperature code
works.

Signed-off-by: Kevin O'Connor <kevin@koconnor.net>
2018-01-03 10:44:01 -05:00
Kevin O'Connor fda988889b heater: Avoid math errors on extreme ADC readings
Avoid log(0) and divide by zero errors in the thermistor calc_temp()
method.

Signed-off-by: Kevin O'Connor <kevin@koconnor.net>
2017-11-13 11:07:20 -05:00
Kevin O'Connor d03cf2b83f adccmds: Continue to query analog inputs after a shutdown
Continue to sample the ADC input pins even if the MCU goes into a
shutdown state.  This enables the printer to continue reporting
temperatures even on an mcu error.

Signed-off-by: Kevin O'Connor <kevin@koconnor.net>
2017-10-12 11:59:27 -04:00
Kevin O'Connor 8d5a9143bb klippy: Avoid using '%' syntax when calling logging module
The logging module can build strings directly from printf syntax - no
need to build the string first.

Signed-off-by: Kevin O'Connor <kevin@koconnor.net>
2017-09-27 12:38:20 -04:00
Kevin O'Connor b9586bad18 mcu: Use is_fileoutput() externally
Use mcu.is_fileoutput() instead of looking up the "debugoutput" flag
in the start args.

Signed-off-by: Kevin O'Connor <kevin@koconnor.net>
2017-09-19 17:22:29 -04:00
Kevin O'Connor ec7990796a pins: Support registering arbitrary chips that supply configurable pins
Allow multiple chips to provide pin mappings (not just the main mcu
chip).  Move the pin parsing from the mcu.py code to pins.py and
support mapping from pin descriptions to their corresponding chips and
parameters.

Signed-off-by: Kevin O'Connor <kevin@koconnor.net>
2017-08-25 20:38:55 -04:00
Kevin O'Connor 268834e4ae klippy: Store printer startup parameters in new "start_args" dictionary
Store pertinent information from the software startup in a dictionary
that the various printer components can access instead of in
individual variables in the Printer() class.  This makes it easier to
add future command-line options.

Signed-off-by: Kevin O'Connor <kevin@koconnor.net>
2017-08-25 19:27:05 -04:00
Kevin O'Connor b80c488d36 heater: Another minor cleanup to Steinhart-Hart math
Signed-off-by: Kevin O'Connor <kevin@koconnor.net>
2017-08-20 12:42:50 -04:00
Kevin O'Connor f25cb33367 heater: Minor cleanup to Steinhart-Hart math
Signed-off-by: Kevin O'Connor <kevin@koconnor.net>
2017-08-18 13:28:04 -04:00
Kevin O'Connor 4b5f3bec4b heater: Add support for a generic "NTC 100K beta 3950" thermistor
Signed-off-by: Kevin O'Connor <kevin@koconnor.net>
2017-08-17 15:12:51 -04:00
Kevin O'Connor 1f4c6443ef heater: Calibrate thermistor directly from temperature and resistance
Store the underlying temperature and resistance values instead of the
Steinhart-Hart coefficents obtained from them.  This makes it easier
to add new thermistors.

Signed-off-by: Kevin O'Connor <kevin@koconnor.net>
2017-08-17 13:26:51 -04:00
Kevin O'Connor d981973096 heater: Fix auto-tune code
Make sure the heater.target_temp is set during the auto-tune test so
that the heater.set_pwm() command will allow the heater to be turned
on.

Signed-off-by: Kevin O'Connor <kevin@koconnor.net>
2017-06-22 12:09:55 -04:00