Commit Graph

14 Commits

Author SHA1 Message Date
Kevin O'Connor 17123889f6 heaters: Make heater.py an "extras" module
The heater logic is an independent module that does not need to be
treated as part of the "core" klipper code.

Signed-off-by: Kevin O'Connor <kevin@koconnor.net>
2020-04-25 14:26:45 -04:00
Kevin O'Connor c197fdb03d heater: Fix misspelling of Celsius
Signed-off-by: Kevin O'Connor <kevin@koconnor.net>
2020-02-27 11:31:51 -05:00
Kevin O'Connor 3e1c42da80 thermistor: Add support for printers with an "inline_resistor"
Signed-off-by: Kevin O'Connor <kevin@koconnor.net>
2019-06-02 10:59:23 -04:00
Kevin O'Connor d6d23c8415 thermistor: Wrap code to 80 columns
Signed-off-by: Kevin O'Connor <kevin@koconnor.net>
2019-02-27 13:29:41 -05:00
Kevin O'Connor bb4fab5570 heater: Rename add_sensor() to add_sensor_factory()
Signed-off-by: Douglas Hammond <wizhippo@gmail.com>
Signed-off-by: Kevin O'Connor <kevin@koconnor.net>
2019-02-25 20:34:12 -05:00
Kevin O'Connor 99980817c3 adc_temperature: Move PrinterADCtoTemperature to adc_temperature.py
Move the low-level PrinterADCtoTemperature() class from thermistor.py
to adc_temperature.py and use it from the Linear() class.

Signed-off-by: Kevin O'Connor <kevin@koconnor.net>
2019-01-21 20:24:51 -05:00
Kevin O'Connor 0c4fc64ef8 thermistor: Separate thermistor configuration from basic ADC callback logic
Signed-off-by: Kevin O'Connor <kevin@koconnor.net>
2019-01-21 18:38:12 -05:00
Kevin O'Connor 293366d033 thermistor: Breakout thermistor math to its own class
Separate the thermistor math from the heater temperature callback
system.  This may make it easier for debugging.

Signed-off-by: Kevin O'Connor <kevin@koconnor.net>
2019-01-20 18:51:00 -05:00
Kevin O'Connor 7fe14f05e6 thermistor: Avoid divide by zero error if min_temp=-273.15
Reported by @TheGuv.

Signed-off-by: Kevin O'Connor <kevin@koconnor.net>
2019-01-04 12:47:37 -05:00
Kevin O'Connor 0dbfa915de adccmds: Add support for min/max temperature check filtering
Extend the ADC out of range check so that it is possible to sample
multiple times before going into a shutdown state.  This reduces the
chance that measurement noise will cause an error.  In an actual over
temperature (or under temperature event) it is expected that the
sensor will consistently report the problem, so extra checks for an
additional second or two should not substantially increase risk.

Signed-off-by: Kevin O'Connor <kevin@koconnor.net>
2018-07-02 13:56:34 -04:00
Kevin O'Connor 1f11c171c7 thermistor: Add Honeywell 100K and MGB18 thermistor definitions
Add two additional thermistors (as suggested by Tim Miller).

Signed-off-by: Kevin O'Connor <kevin@koconnor.net>
2018-04-30 16:08:17 -04:00
Kevin O'Connor 75b89f5261 thermistor: Fallback to using beta if Steinhart-Hart c3 is negative
If the c3 coefficient is negative it can cause the adc calculations to
fail.  The c3 shouldn't be negative in practice, so fallback to a
simple beta calculation in that case.

Signed-off-by: Kevin O'Connor <kevin@koconnor.net>
2018-04-09 12:35:18 -04:00
Kevin O'Connor 8c8261ba80 thermistor: Add support for defining custom thermistors
Add the ability to define a new thermistor type in the config file.

Signed-off-by: Kevin O'Connor <kevin@koconnor.net>
2018-04-09 12:17:39 -04:00
Kevin O'Connor 06d73207e7 heater: Move Thermistor and Linear to their own files in extras/
Move the Thermistor code to a new thermistor.py module.  Move the
Linear code to a new adc_temperature.py module.  This simplifies the
heater.py code.

Signed-off-by: Kevin O'Connor <kevin@koconnor.net>
2018-04-04 23:14:55 -04:00