Recipient with type PERSONAL type_id 1 is a Recipient for a system bot,
since those get created first. Even if it doesn't break tests, it's
still bad, because it is not the intention of those tests to simulate a
cross-realm private message to a system bot.
This is preparatory commit for #18941.
Importing `do_delete_message` from `message_edit.py` was causing a
circular import error. In order to avoid that, we create a separate
message_delete.py file which has all the functions related to deleting
messages.
The tests for deleting messages are present in
`zerver/tests/test_message_edit.py`.
Fixes a part of #18941
django.request logs responses with 5xx response codes (our configuration
of the logger prevents it from logging 4xx as well which it normally
does too). However, it does it without the traceback which results in
quite unhelpful log message that look like
"Bad Gateway:/api/v1/users/me/apns_device_token" - particularly
confusing when sent via email to server admins.
The solution here is to do the logging ourselves, using Django's
log_response() (which is meant for this purpose), and including the
traceback. Django tracks (via response._has_been_logged attribute) that
the response has already been logged, and knows to not duplicate that
action. See log_response() in django's codebase for these details.
Fixes#19596.
It seems helpful for this to get logged with the traceback rather than
just the general
"<exception name> while trying to connect to push notification bouncer."
This allows us to separate the zilencer paths from other JSON paths,
with explicit type annotation expecting `RemoteZulipServer` as the
second parameter of the handler using
authenticated_remote_server_view.
The test case is also updated to remove a test for a situation that no
longer occurs anymore, since we don't perform subdomain checks on
remote servers.
Signed-off-by: Zixuan James Li <p359101898@gmail.com>
Removes `token_kind` parameter being passed to
`remove_apns_device_token` and `remove_android_reg_id` code
paths / endpoints. Possibly missed in a refactor of this
function as the tests for adding these tokens do not pass
a `token_kind` parameter.
Removes `zulip_org_id` and `zulip_org_kay` from code testing
`deactivate_remote_server`. These parameters are passed when
a remote server is added, so possibly a copy and paste error
when these tests were written / last refactored.
Previous behavior was logging only the uuid if it was provided by the
remote server, but that's insufficient, because the user may actually
have no devices registered with uuis and we (at the bouncer) end up
sending notifications to id-based registrations. Not having that id
logged makes it impossible to figure out what's going on.
Fixes#18017.
In previous commits, the change to the bouncer API was introduced to
support this and then a series of migrations added .uuid to
UserProfiles.
Now the code for self-hosted servers that makes requests
to the bouncer is changed to make use of it.
This is the first step to making the full switch to self-hosted servers
use user uuids, per issue #18017. The old id format is still supported
of course, for backward compatibility.
This commit is separate in order to allow deploying *just* the bouncer
API change to production first.
When removing notifications, we skip the access control on if the user
still can read them -- they should not have a notification of them,
both because they currently cannot read the message, as well as
because they have already done so.
aioapns 2.1 removed the loop parameter from the aioapns.APNs
constructor, because Python 3.10 removed the loop parameter from the
asyncio.Lock constructor.
Signed-off-by: Anders Kaseorg <anders@zulip.com>
get_remote_server_by_uuid (called in validate_api_key) raises
ValidationError when given an invalid UUID due to how Django handles
UUIDField. We don't want that exception and prefer the ordinary
DoesNotExist exception to be raised.
APNs payloads nest the zulip-custom data further than the top level,
as Android notifications do. This led to APNs data silently never
being truncated; this case was not caught in tests because the mocks
provided the wrong data for the APNs structure.
Adjust to look in the appropriate place within the APNs data, and
truncate that.
As explained in the comments in the code, just doing UUID(string) and
catching ValueError is not enough, because the uuid library sometimes
tries to modify the string to convert it into a valid UUID:
>>> a = '18cedb98-5222-5f34-50a9-fc418e1ba972'
>>> uuid.UUID(a, version=4)
UUID('18cedb98-5222-4f34-90a9-fc418e1ba972')
Given that these values are uuids, it's better to use UUIDField which is
meant for exactly that, rather than an arbitrary CharField.
This requires modifying some tests to use valid uuids.
We now complain if a test author sends a stream message
that does not result in the sender getting a
UserMessage row for the message.
This is basically 100% equivalent to complaining that
the author failed to subscribe the sender to the stream
as part of the test setup, as far as I can tell, so the
AssertionError instructs the author to subscribe the
sender to the stream.
We exempt bots from this check, although it is
plausible we should only exempt the system bots like
the notification bot.
I considered auto-subscribing the sender to the stream,
but that can be a little more expensive than the
current check, and we generally want test setup to be
explicit.
If there is some legitimate way than a subscribed human
sender can't get a UserMessage, then we probably want
an explicit test for that, or we may want to change the
backend to just write a UserMessage row in that
hypothetical situation.
For most tests, including almost all the ones fixed
here, the author just wants their test setup to
realistically reflect normal operation, and often devs
may not realize that Cordelia is not subscribed to
Denmark or not realize that Hamlet is not subscribed to
Scotland.
Some of us don't remember our Shakespeare from high
school, and our stream subscriptions don't even
necessarily reflect which countries the Bard placed his
characters in.
There may also be some legitimate use case where an
author wants to simulate sending a message to an
unsubscribed stream, but for those edge cases, they can
always set allow_unsubscribed_sender to True.
This makes logging more consistent between FCM and APNs codepaths, and
makes clear which user-ids are for local users, and which are opaque
integers namespaced from some remote zulip server.
Being able to determine how many distinct users are getting push
notifications per remote host is useful, as is the distribution of
device counts. This parallels the log line in
handle_push_notification for push notifications from local realms,
handled via the event queue.
aioapns already has a retry loop. By default it retries forever on
ConnectionError and ConnectionClosed, so our own retry loop would
never be reached. Remove our retry loop, and configure aioapns to
retry APNS_MAX_RETRIES times on ConnectionError like the previous
version did. It still retries forever on ConnectionClosed; that’s not
configurable but probably fine.
Signed-off-by: Anders Kaseorg <anders@zulip.com>