# Support for reading acceleration data from an adxl345 chip
#
# Copyright (C) 2020 Kevin O'Connor <kevin@koconnor.net>
#
# This file may be distributed under the terms of the GNU GPLv3 license.
import logging, time, collections, multiprocessing, os
from . import bus
# ADXL345 registers
REG_DEVID = 0x00
REG_BW_RATE = 0x2C
REG_POWER_CTL = 0x2D
REG_DATA_FORMAT = 0x31
REG_FIFO_CTL = 0x38
REG_MOD_READ = 0x80
REG_MOD_MULTI = 0x40
QUERY_RATES = {
25: 0x8, 50: 0x9, 100: 0xa, 200: 0xb, 400: 0xc,
800: 0xd, 1600: 0xe, 3200: 0xf,
}
SCALE = 0.004 * 9.80665 * 1000. # 4mg/LSB * Earth gravity in mm/s**2
Accel_Measurement = collections.namedtuple(
'Accel_Measurement', ('time', 'accel_x', 'accel_y', 'accel_z'))
# Sample results
class ADXL345Results:
def __init__(self):
self.raw_samples = None
self.samples = []
self.drops = self.overflows = 0
self.time_per_sample = self.start_range = self.end_range = 0.
def get_stats(self):
return ("drops=%d,overflows=%d"
",time_per_sample=%.9f,start_range=%.6f,end_range=%.6f"
% (self.drops, self.overflows,
self.time_per_sample, self.start_range, self.end_range))
def setup_data(self, axes_map, raw_samples, end_sequence, overflows,
start1_time, start2_time, end1_time, end2_time):
if not raw_samples or not end_sequence:
return
self.axes_map = axes_map
self.raw_samples = raw_samples
self.overflows = overflows
self.start2_time = start2_time
self.start_range = start2_time - start1_time
self.end_range = end2_time - end1_time
self.total_count = (end_sequence - 1) * 8 + len(raw_samples[-1][1]) // 6
total_time = end2_time - start2_time
self.time_per_sample = time_per_sample = total_time / self.total_count
self.seq_to_time = time_per_sample * 8.
actual_count = sum([len(data)//6 for _, data in raw_samples])
self.drops = self.total_count - actual_count
def decode_samples(self):
if not self.raw_samples:
return self.samples
(x_pos, x_scale), (y_pos, y_scale), (z_pos, z_scale) = self.axes_map
actual_count = 0
self.samples = samples = [None] * self.total_count
for seq, data in self.raw_samples:
d = bytearray(data)
count = len(data)
sdata = [(d[i] | (d[i+1] << 8)) - ((d[i+1] & 0x80) << 9)
for i in range(0, count-1, 2)]
seq_time = self.start2_time + seq * self.seq_to_time
for i in range(count//6):
samp_time = seq_time + i * self.time_per_sample
x = sdata[i*3 + x_pos] * x_scale
y = sdata[i*3 + y_pos] * y_scale
z = sdata[i*3 + z_pos] * z_scale
samples[actual_count] = Accel_Measurement(samp_time, x, y, z)
actual_count += 1
del samples[actual_count:]
return self.samples
def write_to_file(self, filename):
def write_impl():
try:
# Try to re-nice writing process
os.nice(20)
except:
pass
f = open(filename, "w")
f.write("##%s\n#time,accel_x,accel_y,accel_z\n" % (
self.get_stats(),))
samples = self.samples or self.decode_samples()
for t, accel_x, accel_y, accel_z in samples:
f.write("%.6f,%.6f,%.6f,%.6f\n" % (
t, accel_x, accel_y, accel_z))
f.close()
write_proc = multiprocessing.Process(target=write_impl)
write_proc.daemon = True
write_proc.start()
# Printer class that controls measurments
class ADXL345:
def __init__(self, config):
self.printer = config.get_printer()
self.query_rate = 0
self.last_tx_time = 0.
am = {'x': (0, SCALE), 'y': (1, SCALE), 'z': (2, SCALE),
'-x': (0, -SCALE), '-y': (1, -SCALE), '-z': (2, -SCALE)}
axes_map = config.get('axes_map', 'x,y,z').split(',')
if len(axes_map) != 3 or any([a.strip() not in am for a in axes_map]):
raise config.error("Invalid adxl345 axes_map parameter")
self.axes_map = [am[a.strip()] for a in axes_map]
self.data_rate = config.getint('rate', 3200)
if self.data_rate not in QUERY_RATES:
raise config.error("Invalid rate parameter: %d" % (self.data_rate,))
# Measurement storage (accessed from background thread)
self.raw_samples = []
self.last_sequence = 0
self.samples_start1 = self.samples_start2 = 0.
# Setup mcu sensor_adxl345 bulk query code
self.spi = bus.MCU_SPI_from_config(config, 3, default_speed=5000000)
self.mcu = mcu = self.spi.get_mcu()
self.oid = oid = mcu.create_oid()
self.query_adxl345_cmd = self.query_adxl345_end_cmd =None
mcu.add_config_cmd("config_adxl345 oid=%d spi_oid=%d"
% (oid, self.spi.get_oid()))
mcu.add_config_cmd("query_adxl345 oid=%d clock=0 rest_ticks=0"
% (oid,), on_restart=True)
mcu.register_config_callback(self._build_config)
mcu.register_response(self._handle_adxl345_start, "adxl345_start", oid)
mcu.register_response(self._handle_adxl345_data, "adxl345_data", oid)
# Register commands
self.name = "default"
if len(config.get_name().split()) > 1:
self.name = config.get_name().split()[1]
gcode = self.printer.lookup_object('gcode')
gcode.register_mux_command("ACCELEROMETER_MEASURE", "CHIP", self.name,
self.cmd_ACCELEROMETER_MEASURE,
desc=self.cmd_ACCELEROMETER_MEASURE_help)
gcode.register_mux_command("ACCELEROMETER_QUERY", "CHIP", self.name,
self.cmd_ACCELEROMETER_QUERY,
desc=self.cmd_ACCELEROMETER_QUERY_help)
if self.name == "default":
gcode.register_mux_command("ACCELEROMETER_MEASURE", "CHIP", None,
self.cmd_ACCELEROMETER_MEASURE)
gcode.register_mux_command("ACCELEROMETER_QUERY", "CHIP", None,
self.cmd_ACCELEROMETER_QUERY)
def _build_config(self):
self.query_adxl345_cmd = self.mcu.lookup_command(
"query_adxl345 oid=%c clock=%u rest_ticks=%u",
cq=self.spi.get_command_queue())
self.query_adxl345_end_cmd = self.mcu.lookup_query_command(
"query_adxl345 oid=%c clock=%u rest_ticks=%u",
"adxl345_end oid=%c end1_time=%u end2_time=%u"
" limit_count=%hu sequence=%hu",
oid=self.oid, cq=self.spi.get_command_queue())
def _clock_to_print_time(self, clock):
return self.mcu.clock_to_print_time(self.mcu.clock32_to_clock64(clock))
def _handle_adxl345_start(self, params):
self.samples_start1 = self._clock_to_print_time(params['start1_time'])
self.samples_start2 = self._clock_to_print_time(params['start2_time'])
def _handle_adxl345_data(self, params):
last_sequence = self.last_sequence
sequence = (last_sequence & ~0xffff) | params['sequence']
if sequence < last_sequence:
sequence += 0x10000
self.last_sequence = sequence
raw_samples = self.raw_samples
if len(raw_samples) >= 300000:
# Avoid filling up memory with too many samples
return
raw_samples.append((sequence, params['data']))
def _convert_sequence(self, sequence):
sequence = (self.last_sequence & ~0xffff) | sequence
if sequence < self.last_sequence:
sequence += 0x10000
return sequence
def start_measurements(self, rate=None):
rate = rate or self.data_rate
# Verify chip connectivity
params = self.spi.spi_transfer([REG_DEVID | REG_MOD_READ, 0x00])
response = bytearray(params['response'])
if response[1] != 0xe5:
raise self.printer.command_error("Invalid adxl345 id (got %x vs %x)"
% (response[1], 0xe5))
# Setup chip in requested query rate
clock = 0
if self.last_tx_time:
clock = self.mcu.print_time_to_clock(self.last_tx_time)
self.spi.spi_send([REG_POWER_CTL, 0x00], minclock=clock)
self.spi.spi_send([REG_FIFO_CTL, 0x00])
self.spi.spi_send([REG_DATA_FORMAT, 0x0B])
self.spi.spi_send([REG_BW_RATE, QUERY_RATES[rate]])
self.spi.spi_send([REG_FIFO_CTL, 0x80])
# Setup samples
print_time = self.printer.lookup_object('toolhead').get_last_move_time()
self.raw_samples = []
self.last_sequence = 0
self.samples_start1 = self.samples_start2 = print_time
# Start bulk reading
reqclock = self.mcu.print_time_to_clock(print_time)
rest_ticks = self.mcu.seconds_to_clock(4. / rate)
self.last_tx_time = print_time
self.query_rate = rate
self.query_adxl345_cmd.send([self.oid, reqclock, rest_ticks],
reqclock=reqclock)
def finish_measurements(self):
query_rate = self.query_rate
if not query_rate:
return ADXL345Results()
# Halt bulk reading
print_time = self.printer.lookup_object('toolhead').get_last_move_time()
clock = self.mcu.print_time_to_clock(print_time)
params = self.query_adxl345_end_cmd.send([self.oid, 0, 0],
minclock=clock)
self.last_tx_time = print_time
self.query_rate = 0
raw_samples = self.raw_samples
self.raw_samples = []
# Generate results
end1_time = self._clock_to_print_time(params['end1_time'])
end2_time = self._clock_to_print_time(params['end2_time'])
end_sequence = self._convert_sequence(params['sequence'])
overflows = params['limit_count']
res = ADXL345Results()
res.setup_data(self.axes_map, raw_samples, end_sequence, overflows,
self.samples_start1, self.samples_start2,
end1_time, end2_time)
logging.info("ADXL345 finished %d measurements: %s",
res.total_count, res.get_stats())
return res
def end_query(self, name):
if not self.query_rate:
return
res = self.finish_measurements()
# Write data to file
if self.name == "default":
filename = "/tmp/adxl345-%s.csv" % (name,)
else:
filename = "/tmp/adxl345-%s-%s.csv" % (self.name, name,)
res.write_to_file(filename)
cmd_ACCELEROMETER_MEASURE_help = "Start/stop accelerometer"
def cmd_ACCELEROMETER_MEASURE(self, gcmd):
if self.query_rate:
name = gcmd.get("NAME", time.strftime("%Y%m%d_%H%M%S"))
if not name.replace('-', '').replace('_', '').isalnum():
raise gcmd.error("Invalid adxl345 NAME parameter")
self.end_query(name)
gcmd.respond_info("adxl345 measurements stopped")
else:
rate = gcmd.get_int("RATE", self.data_rate)
if rate not in QUERY_RATES:
raise gcmd.error("Not a valid adxl345 query rate: %d" % (rate,))
self.start_measurements(rate)
gcmd.respond_info("adxl345 measurements started")
cmd_ACCELEROMETER_QUERY_help = "Query accelerometer for the current values"
def cmd_ACCELEROMETER_QUERY(self, gcmd):
if self.query_rate:
raise gcmd.error("adxl345 measurements in progress")
self.start_measurements()
reactor = self.printer.get_reactor()
eventtime = starttime = reactor.monotonic()
while not self.raw_samples:
eventtime = reactor.pause(eventtime + .1)
if eventtime > starttime + 3.:
# Try to shutdown the measurements
self.finish_measurements()
raise gcmd.error("Timeout reading adxl345 data")
result = self.finish_measurements()
values = result.decode_samples()
_, accel_x, accel_y, accel_z = values[-1]
gcmd.respond_info("adxl345 values (x, y, z): %.6f, %.6f, %.6f" % (
accel_x, accel_y, accel_z))
def load_config(config):
return ADXL345(config)
def load_config_prefix(config):