klipper-dgus/klippy/extras/replicape.py

252 lines
11 KiB
Python

# Code to configure miscellaneous chips
#
# Copyright (C) 2017,2018 Kevin O'Connor <kevin@koconnor.net>
#
# This file may be distributed under the terms of the GNU GPLv3 license.
import logging
import pins, mcu, bus
REPLICAPE_MAX_CURRENT = 3.84
REPLICAPE_SHIFT_REGISTER_BUS = "spidev1.1"
REPLICAPE_PCA9685_BUS = 2
REPLICAPE_PCA9685_ADDRESS = 0x70
REPLICAPE_PCA9685_CYCLE_TIME = .001
PIN_MIN_TIME = 0.100
class pca9685_pwm:
def __init__(self, replicape, channel, pin_type, pin_params):
self._replicape = replicape
self._channel = channel
if pin_type not in ['digital_out', 'pwm']:
raise pins.error("Pin type not supported on replicape")
self._mcu = replicape.host_mcu
self._mcu.register_config_callback(self._build_config)
self._bus = REPLICAPE_PCA9685_BUS
self._address = REPLICAPE_PCA9685_ADDRESS
self._cycle_time = REPLICAPE_PCA9685_CYCLE_TIME
self._max_duration = 2.
self._oid = None
self._invert = pin_params['invert']
self._start_value = self._shutdown_value = float(self._invert)
self._is_static = False
self._last_clock = 0
self._pwm_max = 0.
self._set_cmd = None
def get_mcu(self):
return self._mcu
def setup_max_duration(self, max_duration):
self._max_duration = max_duration
def setup_cycle_time(self, cycle_time, hardware_pwm=False):
if hardware_pwm:
raise pins.error("pca9685 does not support hardware_pwm parameter")
if cycle_time != self._cycle_time:
logging.info("Ignoring pca9685 cycle time of %.6f (using %.6f)",
cycle_time, self._cycle_time)
def setup_start_value(self, start_value, shutdown_value, is_static=False):
if is_static and start_value != shutdown_value:
raise pins.error("Static pin can not have shutdown value")
if self._invert:
start_value = 1. - start_value
shutdown_value = 1. - shutdown_value
self._start_value = max(0., min(1., start_value))
self._shutdown_value = max(0., min(1., shutdown_value))
self._is_static = is_static
self._replicape.note_pwm_start_value(
self._channel, self._start_value, self._shutdown_value)
def _build_config(self):
self._pwm_max = self._mcu.get_constant_float("PCA9685_MAX")
cycle_ticks = self._mcu.seconds_to_clock(self._cycle_time)
if self._is_static:
self._mcu.add_config_cmd(
"set_pca9685_out bus=%d addr=%d channel=%d"
" cycle_ticks=%d value=%d" % (
self._bus, self._address, self._channel,
cycle_ticks, self._start_value * self._pwm_max))
return
self._oid = self._mcu.create_oid()
self._mcu.add_config_cmd(
"config_pca9685 oid=%d bus=%d addr=%d channel=%d cycle_ticks=%d"
" value=%d default_value=%d max_duration=%d" % (
self._oid, self._bus, self._address, self._channel, cycle_ticks,
self._start_value * self._pwm_max,
self._shutdown_value * self._pwm_max,
self._mcu.seconds_to_clock(self._max_duration)))
cmd_queue = self._mcu.alloc_command_queue()
self._set_cmd = self._mcu.lookup_command(
"schedule_pca9685_out oid=%c clock=%u value=%hu", cq=cmd_queue)
def set_pwm(self, print_time, value):
clock = self._mcu.print_time_to_clock(print_time)
if self._invert:
value = 1. - value
value = int(max(0., min(1., value)) * self._pwm_max + 0.5)
self._replicape.note_pwm_enable(print_time, self._channel, value)
self._set_cmd.send([self._oid, clock, value],
minclock=self._last_clock, reqclock=clock)
self._last_clock = clock
def set_digital(self, print_time, value):
if value:
self.set_pwm(print_time, 1.)
else:
self.set_pwm(print_time, 0.)
class ReplicapeDACEnable:
def __init__(self, replicape, channel, pin_type, pin_params):
if pin_type != 'digital_out':
raise pins.error("Replicape virtual enable pin must be digital_out")
if pin_params['invert']:
raise pins.error("Replicape virtual enable pin can not be inverted")
self.mcu = replicape.host_mcu
self.value = replicape.stepper_dacs[channel]
self.pwm = pca9685_pwm(replicape, channel, pin_type, pin_params)
def get_mcu(self):
return self.mcu
def setup_max_duration(self, max_duration):
self.pwm.setup_max_duration(max_duration)
def set_digital(self, print_time, value):
if value:
self.pwm.set_pwm(print_time, self.value)
else:
self.pwm.set_pwm(print_time, 0.)
SERVO_PINS = {
"servo0": ("pwmchip0/pwm0", "gpio0_30", "gpio1_18"), # P9_11, P9_14
"servo1": ("pwmchip0/pwm1", "gpio3_17", "gpio1_19"), # P9_28, P9_16
}
class servo_pwm:
def __init__(self, replicape, pin_params):
config_name = pin_params['pin']
pwm_pin, resv1, resv2 = SERVO_PINS[config_name]
pin_params = dict(pin_params)
pin_params['pin'] = pwm_pin
# Setup actual pwm pin using linux hardware pwm on host
self.mcu_pwm = replicape.host_mcu.setup_pin("pwm", pin_params)
self.get_mcu = self.mcu_pwm.get_mcu
self.setup_max_duration = self.mcu_pwm.setup_max_duration
self.setup_start_value = self.mcu_pwm.setup_start_value
self.set_pwm = self.mcu_pwm.set_pwm
# Reserve pins to warn user of conflicts
pru_mcu = replicape.mcu_pwm_enable.get_mcu()
printer = pru_mcu.get_printer()
ppins = printer.lookup_object('pins')
ppins.reserve_pin(pru_mcu.get_name(), resv1, config_name)
ppins.reserve_pin(pru_mcu.get_name(), resv2, config_name)
def setup_cycle_time(self, cycle_time, hardware_pwm=False):
self.mcu_pwm.setup_cycle_time(cycle_time, True);
ReplicapeStepConfig = {
'disable': None,
'1': (1<<7)|(1<<5), '2': (1<<7)|(1<<5)|(1<<6), 'spread2': (1<<5),
'4': (1<<7)|(1<<5)|(1<<4), '16': (1<<7)|(1<<5)|(1<<6)|(1<<4),
'spread4': (1<<5)|(1<<4), 'spread16': (1<<7), 'stealth4': (1<<7)|(1<<6),
'stealth16': 0
}
class Replicape:
def __init__(self, config):
printer = config.get_printer()
ppins = printer.lookup_object('pins')
ppins.register_chip('replicape', self)
revisions = {'B3': 'B3'}
config.getchoice('revision', revisions)
self.host_mcu = mcu.get_printer_mcu(printer, config.get('host_mcu'))
# Setup enable pin
enable_pin = config.get('enable_pin', '!P9_41')
self.mcu_pwm_enable = ppins.setup_pin('digital_out', enable_pin)
self.mcu_pwm_enable.setup_max_duration(0.)
self.mcu_pwm_start_value = self.mcu_pwm_shutdown_value = False
# Setup power pins
self.pins = {
"power_e": (pca9685_pwm, 5), "power_h": (pca9685_pwm, 3),
"power_hotbed": (pca9685_pwm, 4),
"power_fan0": (pca9685_pwm, 7), "power_fan1": (pca9685_pwm, 8),
"power_fan2": (pca9685_pwm, 9), "power_fan3": (pca9685_pwm, 10) }
self.servo_pins = {
"servo0": 3, "servo1": 2 }
# Setup stepper config
self.last_stepper_time = 0.
self.stepper_dacs = {}
shift_registers = [1, 0, 0, 1, 1]
for port, name in enumerate('xyzeh'):
prefix = 'stepper_%s_' % (name,)
sc = config.getchoice(
prefix + 'microstep_mode', ReplicapeStepConfig, 'disable')
if sc is None:
continue
sc |= shift_registers[port]
if config.getboolean(prefix + 'chopper_off_time_high', False):
sc |= 1<<3
if config.getboolean(prefix + 'chopper_hysteresis_high', False):
sc |= 1<<2
if config.getboolean(prefix + 'chopper_blank_time_high', True):
sc |= 1<<1
shift_registers[port] = sc
channel = port + 11
cur = config.getfloat(
prefix + 'current', above=0., maxval=REPLICAPE_MAX_CURRENT)
self.stepper_dacs[channel] = cur / REPLICAPE_MAX_CURRENT
self.pins[prefix + 'enable'] = (ReplicapeDACEnable, channel)
self.enabled_channels = {ch: False for cl, ch in self.pins.values()}
self.sr_disabled = list(reversed(shift_registers))
if [i for i in [0, 1, 2] if 11+i in self.stepper_dacs]:
# Enable xyz steppers
shift_registers[0] &= ~1
if [i for i in [3, 4] if 11+i in self.stepper_dacs]:
# Enable eh steppers
shift_registers[3] &= ~1
if (config.getboolean('standstill_power_down', False)
and self.stepper_dacs):
shift_registers[4] &= ~1
self.sr_enabled = list(reversed(shift_registers))
self.sr_spi = bus.MCU_SPI(self.host_mcu, REPLICAPE_SHIFT_REGISTER_BUS,
None, 0, 50000000, self.sr_disabled)
self.sr_spi.spi_send(self.sr_disabled)
def note_pwm_start_value(self, channel, start_value, shutdown_value):
self.mcu_pwm_start_value |= not not start_value
self.mcu_pwm_shutdown_value |= not not shutdown_value
self.mcu_pwm_enable.setup_start_value(
self.mcu_pwm_start_value, self.mcu_pwm_shutdown_value)
self.enabled_channels[channel] = not not start_value
def note_pwm_enable(self, print_time, channel, value):
is_enable = not not value
if self.enabled_channels[channel] == is_enable:
# Nothing to do
return
self.enabled_channels[channel] = is_enable
# Check if need to set the pca9685 enable pin
on_channels = [1 for c, e in self.enabled_channels.items() if e]
if not on_channels:
self.mcu_pwm_enable.set_digital(print_time, 0)
elif is_enable and len(on_channels) == 1:
self.mcu_pwm_enable.set_digital(print_time, 1)
# Check if need to set the stepper enable lines
if channel not in self.stepper_dacs:
return
on_dacs = [1 for c in self.stepper_dacs.keys()
if self.enabled_channels[c]]
if not on_dacs:
sr = self.sr_disabled
elif is_enable and len(on_dacs) == 1:
sr = self.sr_enabled
else:
return
print_time = max(print_time, self.last_stepper_time + PIN_MIN_TIME)
clock = self.host_mcu.print_time_to_clock(print_time)
self.sr_spi.spi_send(sr, minclock=clock, reqclock=clock)
def setup_pin(self, pin_type, pin_params):
pin = pin_params['pin']
if pin in self.pins:
pclass, channel = self.pins[pin]
return pclass(self, channel, pin_type, pin_params)
elif pin in self.servo_pins:
# enable servo pins via shift registers
index = self.servo_pins[pin]
self.sr_enabled[index] |= 1
self.sr_disabled[index] |= 1
self.sr_spi.spi_send(self.sr_disabled)
return servo_pwm(self, pin_params)
raise pins.error("Unknown replicape pin %s" % (pin,))
def load_config(config):