klipper-dgus/klippy/extras/bme280.py

203 lines
7.3 KiB
Python

# Support for i2c based temperature sensors
#
# Copyright (C) 2020 Eric Callahan <arksine.code@gmail.com>
#
# This file may be distributed under the terms of the GNU GPLv3 license.
import bus
import logging
REPORT_TIME = .8
BME280_CHIP_ADDR = 0x76
BME280_REGS = {
'CHIP_ID': 0xD0, 'RESET': 0xE0, 'CTRL_HUM': 0xF2,
'STATUS': 0xF3, 'CTRL_MEAS': 0xF4, 'CONFIG': 0xF5,
'PRESSURE_MSB': 0xF7, 'PRESSURE_LSB': 0xF8, 'PRESSURE_XLSB': 0xF9,
'TEMP_MSB': 0xFA, 'TEMP_LSB': 0xFB, 'TEMP_XLSB': 0xFC,
'HUM_MSB': 0xFD, 'HUM_LSB': 0xFE, 'CAL_1': 0x88, 'CAL_2': 0xE1
}
# BME default settings
STATUS_MEASURING = 1 << 3
STATUS_IM_UPDATE = 1
MODE = 1
class BME280:
def __init__(self, config):
self.printer = config.get_printer()
self.name = config.get_name().split()[-1]
self.reactor = self.printer.get_reactor()
self.i2c = bus.MCU_I2C_from_config(
config, default_addr=BME280_CHIP_ADDR, default_speed=100000)
self.os_temp = config.getint('bme280_oversample_temp', 2)
self.os_hum = config.getint('bme280_oversample_hum', 2)
self.os_pres = config.getint('bme280_oversample_pressure', 2)
self.temp = self.pressure = self.humidity = self.t_fine = 0.
self.max_sample_time = \
(1.25 + (2.3 * self.os_temp) + ((2.3 * self.os_pres) +
.575) + ((2.3 * self.os_hum) + .575)) / 1000
self.dig = None
self.sample_timer = self.reactor.register_timer(self._sample_bme280)
self.printer.add_object("bme280 " + self.name, self)
self.printer.register_event_handler("klippy:ready", self.handle_ready)
def handle_ready(self):
self._init_bme280()
self.reactor.update_timer(self.sample_timer, self.reactor.NOW)
def setup_minmax(self, min_temp, max_temp):
pass
def setup_callback(self, cb):
self._callback = cb
def get_report_time_delta(self):
return REPORT_TIME
def _init_bme280(self):
def get_twos_complement(val, bit_size):
if val & (1 << (bit_size - 1)):
val -= (1 << bit_size)
return val
def get_unsigned_short(bits):
return bits[1] << 8 | bits[0]
def get_signed_short(bits):
val = get_unsigned_short(bits)
return get_twos_complement(val, 16)
# Check the chip ID, should be 0x60
chip_id = self.read_register('CHIP_ID', 1)[0]
if chip_id != 0x60:
logging.info(
"bme280: Chip ID mismatch, expected 0x60, received %#x"
% (chip_id))
# Make sure non-volatile memory has been copied to registers
status = self.read_register('STATUS', 1)[0]
while status & STATUS_IM_UPDATE:
self.reactor.pause(self.reactor.monotonic() + .01)
status = self.read_register('STATUS', 1)[0]
c1 = self.read_register('CAL_1', 26)
c2 = self.read_register('CAL_2', 7)
# Read out and calculate the trimming parameters
dig = {}
unsigned_keys = ['T1', 'P1']
idx = 0
for cnt, prefix in [(3, 'T'), (9, 'P')]:
for i in range(cnt):
key = prefix + str(i + 1)
if key in unsigned_keys:
dig[key] = get_unsigned_short(c1[idx:idx+2])
else:
dig[key] = get_signed_short(c1[idx:idx+2])
idx += 2
dig['H1'] = c1[25] & 0xFF
dig['H2'] = get_signed_short(c2[0:2])
dig['H3'] = c2[2] & 0xFF
dig['H4'] = get_twos_complement(
((c2[3] << 4) & 0xFF0) | (c2[4] & 0x0F), 12)
dig['H5'] = get_twos_complement(
(c2[4] & 0x0F) | ((c2[5] << 4) & 0xFF0), 12)
dig['H6'] = get_twos_complement(c2[6], 8)
self.dig = dig
def _sample_bme280(self, eventtime):
# Enter forced mode
self.write_register('CTRL_HUM', self.os_hum)
meas = self.os_temp << 5 | self.os_pres << 2 | MODE
self.write_register('CTRL_MEAS', meas)
try:
# wait until results are ready
status = self.read_register('STATUS', 1)[0]
while status & STATUS_MEASURING:
self.reactor.pause(
self.reactor.monotonic() + self.max_sample_time)
status = self.read_register('STATUS', 1)[0]
data = self.read_register('PRESSURE_MSB', 8)
except Exception:
logging.exception("BME280: Error reading data")
self.temp = self.pressure = self.humidity = .0
return self.reactor.NEVER
pressure_raw = (data[0] << 12) | (data[1] << 4) | (data[2] >> 4)
temp_raw = (data[3] << 12) | (data[4] << 4) | (data[5] >> 4)
humid_raw = (data[6] << 8) | data[7]
self.temp = self._compensate_temp(temp_raw)
self.pressure = self._compensate_pressure(pressure_raw) / 100.
self.humidity = self._compensate_humidity(humid_raw)
measured_time = self.reactor.monotonic()
self._callback(measured_time, self.temp)
return measured_time + REPORT_TIME
def _compensate_temp(self, raw_temp):
dig = self.dig
var1 = ((raw_temp / 16384. - (dig['T1'] / 1024.)) * dig['T2'])
var2 = (
((raw_temp / 131072.) - (dig['T1'] / 8192.)) *
((raw_temp / 131072.) - (dig['T1'] / 8192.)) * dig['T3'])
self.t_fine = var1 + var2
return self.t_fine / 5120.0
def _compensate_pressure(self, raw_pressure):
dig = self.dig
t_fine = self.t_fine
var1 = t_fine / 2. - 64000.
var2 = var1 * var1 * dig['P6'] / 32768.
var2 = var2 + var1 * dig['P5'] * 2.
var2 = var2 / 4. + (dig['P4'] * 65536.)
var1 = (dig['P3'] * var1 * var1 / 524288. + dig['P2'] * var1) / 524288.
var1 = (1. + var1 / 32768.) * dig['P1']
if var1 == 0:
return 0.
else:
pressure = 1048576.0 - raw_pressure
pressure = ((pressure - var2 / 4096.) * 6250.) / var1
var1 = dig['P9'] * pressure * pressure / 2147483648.
var2 = pressure * dig['P8'] / 32768.
return pressure + (var1 + var2 + dig['P7']) / 16.
def _compensate_humidity(self, raw_humidity):
dig = self.dig
t_fine = self.t_fine
humidity = t_fine - 76800.
h1 = (
raw_humidity - (dig['H4'] * 64. + dig['H5'] / 16384. * humidity))
h2 = (dig['H2'] / 65536. * (1. + dig['H6'] / 67108864. * humidity *
(1. + dig['H3'] / 67108864. * humidity)))
humidity = h1 * h2
humidity = humidity * (1. - dig['H1'] * humidity / 524288.)
return min(100., max(0., humidity))
def read_register(self, reg_name, read_len):
# read a single register
regs = [BME280_REGS[reg_name]]
params = self.i2c.i2c_read(regs, read_len)
return bytearray(params['response'])
def write_register(self, reg_name, data):
if type(data) is not list:
data = [data]
reg = BME280_REGS[reg_name]
data.insert(0, reg)
self.i2c.i2c_write(data)
def get_status(self, eventtime):
return {
'temperature': self.temp,
'humidity': self.humidity,
'pressure': self.pressure
}
def load_config(config):
# Register sensor
pheaters = config.get_printer().try_load_module(config, "heaters")
pheaters.add_sensor_factory("BME280", BME280)