Commit Graph

21 Commits

Author SHA1 Message Date
Kevin O'Connor 64b3e5642e heaters: Make sure set_temp() command wakes up the idle_timeout
Introduce a heaters.set_temperature() command and call that from
commands that set a heater temperature.  This new function calls
toolhead.register_lookahead_callback() so that the idle_timeout gets
notification that activity has occurred.

Signed-off-by: Kevin O'Connor <kevin@koconnor.net>
2021-03-05 18:59:01 -05:00
Kevin O'Connor 5cce7f4d55 pid_calibrate: Update for improved python3 compatibility
Signed-off-by: Kevin O'Connor <kevin@koconnor.net>
2020-09-04 19:30:18 -04:00
Kevin O'Connor f931da1b87 extras: Use "from . import module" for relative imports
Use alternate import syntax to improve Python3 compatibility.

Signed-off-by: Kevin O'Connor <kevin@koconnor.net>
2020-06-15 17:15:53 -04:00
Kevin O'Connor c4de0bba50 pid_calibrate: Avoid internal error on a shutdown
If a shutdown occurs during a PID_CALIBRATE command (eg, due to a
heater problem) then exit cleanly instead of throwing an internal
error.

Signed-off-by: Kevin O'Connor <kevin@koconnor.net>
2020-06-14 11:34:04 -04:00
Kevin O'Connor a79096efdf pid_calibrate: Use new GCodeCommand wrappers
Signed-off-by: Kevin O'Connor <kevin@koconnor.net>
2020-05-05 11:08:11 -04:00
Kevin O'Connor ced389f4f6 pid_calibrate: Fix module import
Signed-off-by: Kevin O'Connor <kevin@koconnor.net>
2020-04-25 14:49:50 -04:00
Kevin O'Connor 17123889f6 heaters: Make heater.py an "extras" module
The heater logic is an independent module that does not need to be
treated as part of the "core" klipper code.

Signed-off-by: Kevin O'Connor <kevin@koconnor.net>
2020-04-25 14:26:45 -04:00
Kevin O'Connor d858498a53 heater: Move M105 command handling from gcode.py to heater.py
Signed-off-by: Kevin O'Connor <kevin@koconnor.net>
2020-04-25 14:26:28 -04:00
Kevin O'Connor 4b6a65c1e0 heater: Do not flush look-ahead queue on a heater temperature update
The print_time parameter of heater.set_temp() is not currently used
and it isn't necessary to flush the look-ahead queue just get the
print_time.  Remove the parameter from heater.set_temp() to avoid
flushing the look-ahead queue.

Signed-off-by: Kevin O'Connor <kevin@koconnor.net>
2020-01-03 18:13:57 -05:00
Kevin O'Connor 0e2d1a190e gcode: Rename bg_temp() to wait_for_temperature()
Signed-off-by: Kevin O'Connor <kevin@koconnor.net>
2019-12-16 19:21:37 -05:00
Kevin O'Connor 665323eb29 heater: Use printer.command_error() instead of internal heater.error()
Use the more standard command_error to report invalid temperature
requests.

Signed-off-by: Kevin O'Connor <kevin@koconnor.net>
2019-12-16 19:16:58 -05:00
Kevin O'Connor 7efbc021a5 pid_calibrate: Add some comments on the calibration methodology
Signed-off-by: Kevin O'Connor <kevin@koconnor.net>
2018-10-19 22:40:11 -04:00
Kevin O'Connor 5a1b2d61ae pid_calibrate: Support saving calibration data via SAVE_CONFIG
Signed-off-by: Kevin O'Connor <kevin@koconnor.net>
2018-09-25 13:48:46 -04:00
Kevin O'Connor b0ee323e2e heater: Introduce smooth_time config option; remove pid_deriv_time
Add generic temperature smoothing to the Heater class.  This is useful
to avoid min_extrude_temp and verify_heater errors due to measurement
noise.

Rename the pid_deriv_time config option to smooth_time so that the
smoothing amount need only be specified once.

Signed-off-by: Kevin O'Connor <kevin@koconnor.net>
2018-07-06 13:47:10 -04:00
Kevin O'Connor 4889e8241d pid_calibrate: Update the heater's target temperature during calibration
Update the target temperature during the pid calibration.  This gives
additional feedback to the user and it makes it less likely that a
verify_heater error will be raised during calibration.

Signed-off-by: Kevin O'Connor <kevin@koconnor.net>
2018-06-27 14:39:20 -04:00
Kevin O'Connor 7e497af184 heater: Don't peak into Heater class member variables
The control classes should not peak into the heater member variables.

Signed-off-by: Kevin O'Connor <kevin@koconnor.net>
2018-06-27 14:32:10 -04:00
Kevin O'Connor 460cc88f3d pid_calibrate: Make sure to unregister new control class on error
Signed-off-by: Kevin O'Connor <kevin@koconnor.net>
2018-04-06 11:39:24 -04:00
Kevin O'Connor 06d73207e7 heater: Move Thermistor and Linear to their own files in extras/
Move the Thermistor code to a new thermistor.py module.  Move the
Linear code to a new adc_temperature.py module.  This simplifies the
heater.py code.

Signed-off-by: Kevin O'Connor <kevin@koconnor.net>
2018-04-04 23:14:55 -04:00
Kevin O'Connor 0fc4f0946e heater: Move adc logic into Thermistor class
The Thermistor (and Linear) class should handle all the details of
reading the ADC values and converting them to temperatures.  So, move
that logic out of the Heater() class.

Signed-off-by: Kevin O'Connor <kevin@koconnor.net>
2018-04-04 23:14:33 -04:00
Kevin O'Connor aed958eb5c heater: Add PrinterHeaters class that stores all sensors and heaters
Add a PrinterHeaters class that can stores references to available
temperature sensors and stores references to instantiated heaters.

Add a extras/heater_bed.py file and delay instantiation of the
heater_bed object.  This allows the heater.py module to be imported
earlier during the setup phase, and allows the PrinterHeaters class to
be available for registering sensors and heaters.

Signed-off-by: Kevin O'Connor <kevin@koconnor.net>
2018-04-04 23:13:53 -04:00
Kevin O'Connor 973ef97143 pid_calibrate: Move PID calibration logic from heater.py to new file
Drop support for M303 and PID_TUNE, and replace it with a new
PID_CALIBRATE command.  Move the logic for this command from heater.py
to a new pid_calibrate.py file in the extras/ directory.

Signed-off-by: Kevin O'Connor <kevin@koconnor.net>
2018-03-18 12:02:30 -04:00