Commit Graph

7 Commits

Author SHA1 Message Date
dawidmpunkt b4ee93043a
htu21d: Update htu21d.py (#4520)
Line 202: should be self.humidity instead of self.temp

Signed-off-by: Dawid Murawski <dawid.m@gmx.net>
2021-08-17 15:52:47 -04:00
Jon Sanders 6c9404ac0c
htu21d: sensor definition fix (#4075)
HTU21D sensor class lacked the method `get_report_time_delta` invoked
during watermark control loops. This short fix simply adds that method
in, calling the `self.report_time` attribute created during class
construction.

Signed-off-by: Jon Sanders <jonsan@gmail.com>
2021-03-18 23:38:07 -04:00
Kevin O'Connor 6e79152f47 htu21d: Implement support for min_temp/max_temp checks
Signed-off-by: Kevin O'Connor <kevin@koconnor.net>
2021-02-01 11:30:27 -05:00
Kevin O'Connor 5d960aef37 htu21d: Fix time reporting of temperature measurements
The temperature callback takes a "print time" not a "system time".

Signed-off-by: Kevin O'Connor <kevin@koconnor.net>
2021-01-24 15:38:16 -05:00
Kevin O'Connor 52c6ba3bb5 htu21d: Start temperature measurements from "klippy:connect" callback
Signed-off-by: Kevin O'Connor <kevin@koconnor.net>
2020-12-01 11:36:37 -05:00
Kevin O'Connor f931da1b87 extras: Use "from . import module" for relative imports
Use alternate import syntax to improve Python3 compatibility.

Signed-off-by: Kevin O'Connor <kevin@koconnor.net>
2020-06-15 17:15:53 -04:00
Lucio Tarantino dac42efbd9
htu21d: Support for HTI21D family sensor on I2C bus (#2803)
Signed-off-by: Lucio Tarantino <lucio.tarantino@gmail.com>
2020-05-03 18:47:24 -04:00