mirror of https://github.com/Desuuuu/klipper.git
mcu: Set reqclock on trsync_start commands
Set the reqclock on trsync commands to ensure those commands do not cause 32-bit timer rollover errors. Otherwise, it may result in "Timer too close" errors. Signed-off-by: Kevin O'Connor <kevin@koconnor.net>
This commit is contained in:
parent
28f60f7ef6
commit
f24210054a
|
@ -107,10 +107,11 @@ class MCU_trsync:
|
|||
self._mcu.register_response(self._handle_trsync_state,
|
||||
"trsync_state", self._oid)
|
||||
self._trsync_start_cmd.send([self._oid, clock, report_ticks,
|
||||
self.REASON_COMMS_TIMEOUT])
|
||||
self.REASON_COMMS_TIMEOUT], reqclock=clock)
|
||||
for s in self._steppers:
|
||||
self._stepper_stop_cmd.send([s.get_oid(), self._oid])
|
||||
self._trsync_set_timeout_cmd.send([self._oid, expire_clock])
|
||||
self._trsync_set_timeout_cmd.send([self._oid, expire_clock],
|
||||
reqclock=expire_clock)
|
||||
def set_home_end_time(self, home_end_time):
|
||||
self._home_end_clock = self._mcu.print_time_to_clock(home_end_time)
|
||||
def stop(self):
|
||||
|
|