From cc31810fa8be6d58b1b9d71f9847cfe9842a7c6a Mon Sep 17 00:00:00 2001 From: Denis Ignatenko <60291791+test3210-d@users.noreply.github.com> Date: Sat, 27 Mar 2021 18:53:40 +0200 Subject: [PATCH] hall_filament_width_sensor: fix range check error (#4113) Signed-off-by: Denis Ignatenko --- klippy/extras/hall_filament_width_sensor.py | 4 ++-- 1 file changed, 2 insertions(+), 2 deletions(-) diff --git a/klippy/extras/hall_filament_width_sensor.py b/klippy/extras/hall_filament_width_sensor.py index 9b244e13..276dd144 100644 --- a/klippy/extras/hall_filament_width_sensor.py +++ b/klippy/extras/hall_filament_width_sensor.py @@ -127,7 +127,7 @@ class HallFilamentWidthSensor: self.runout_helper.note_filament_present( self.diameter > self.runout_dia) # Does filament exists - if self.lastFilamentWidthReading > 0.5: + if self.diameter > 0.5: if len(self.filament_array) > 0: # Get first position in filament array pending_position = self.filament_array[0][0] @@ -160,7 +160,7 @@ class HallFilamentWidthSensor: def cmd_M407(self, gcmd): response = "" - if self.lastFilamentWidthReading > 0: + if self.diameter > 0: response += ("Filament dia (measured mm): " + str(self.diameter)) else: