mirror of https://github.com/Desuuuu/klipper.git
docs: Update Delta_Calibrate.md with probe location bias info
Signed-off-by: Kevin O'Connor <kevin@koconnor.net>
This commit is contained in:
parent
e061029b3a
commit
97adca18c4
|
@ -14,6 +14,22 @@ tower endstop switches. If one is using Trinamic stepper motor drivers
|
||||||
then consider enabling [endstop phase](Endstop_Phase.md) detection to
|
then consider enabling [endstop phase](Endstop_Phase.md) detection to
|
||||||
improve the accuracy of those switches.
|
improve the accuracy of those switches.
|
||||||
|
|
||||||
|
Automatic vs manual probing
|
||||||
|
===========================
|
||||||
|
|
||||||
|
Klipper supports calibrating the delta parameters via a manual probing
|
||||||
|
method or via an automatic Z probe.
|
||||||
|
|
||||||
|
A number of delta printer kits come with automatic Z probes that are
|
||||||
|
not sufficiently accurate (specifically, small differences in arm
|
||||||
|
length can cause effector tilt which can skew an automatic probe). If
|
||||||
|
using an automatic probe then first
|
||||||
|
[calibrate the probe](Probe_Calibrate.md) and then check for a
|
||||||
|
[probe location bias](Probe_Calibrate.md#location-bias-check). If the
|
||||||
|
automatic probe has a bias of more than 25 microns (.025mm) then use
|
||||||
|
manual probing instead. Manual probing only takes a few minutes and it
|
||||||
|
eliminates error introduced by the probe.
|
||||||
|
|
||||||
Basic delta calibration
|
Basic delta calibration
|
||||||
=======================
|
=======================
|
||||||
|
|
||||||
|
@ -39,20 +55,13 @@ calibration completes, one can remove this setting from the config.)
|
||||||
|
|
||||||
There are two ways to perform the probing - manual probing
|
There are two ways to perform the probing - manual probing
|
||||||
(`DELTA_CALIBRATE METHOD=manual`) and automatic probing
|
(`DELTA_CALIBRATE METHOD=manual`) and automatic probing
|
||||||
(`DELTA_CALIBRATE`). Automatic probing utilizes a hardware device
|
(`DELTA_CALIBRATE`). The manual probing method will move the head near
|
||||||
capable of triggering when the toolhead is at a set distance from the
|
the bed and then wait for the user to follow the steps described at
|
||||||
bed. The manual probing method will move the head near the bed and
|
|
||||||
then wait for the user to follow the steps described at
|
|
||||||
["the paper test"](Bed_Level.md#the-paper-test) to determine the
|
["the paper test"](Bed_Level.md#the-paper-test) to determine the
|
||||||
actual distance between the nozzle and bed at the given location. It
|
actual distance between the nozzle and bed at the given location.
|
||||||
is recommended to use manual probing for delta calibration. A number
|
|
||||||
of common printer kits come with probes that are not sufficiently
|
|
||||||
accurate (specifically, small differences in arm length can cause
|
|
||||||
effector tilt which can skew an automatic probe). Manual probing only
|
|
||||||
takes a few minutes and it eliminates error introduced by the probe.
|
|
||||||
|
|
||||||
To perform the basic probe, make sure the config has a
|
To perform the basic probe, make sure the config has a
|
||||||
[delta_calibrate] section defined and run:
|
[delta_calibrate] section defined and then run the tool:
|
||||||
```
|
```
|
||||||
G28
|
G28
|
||||||
DELTA_CALIBRATE METHOD=manual
|
DELTA_CALIBRATE METHOD=manual
|
||||||
|
|
Loading…
Reference in New Issue