config: Simplify description of temperature_fan config options

Signed-off-by: Kevin O'Connor <kevin@koconnor.net>
This commit is contained in:
Kevin O'Connor 2020-10-28 14:45:45 -04:00
parent 56004c0228
commit 6a67afaff1
1 changed files with 13 additions and 32 deletions

View File

@ -1270,19 +1270,19 @@
#off_below:
# See the "fan" section in example.cfg for a description of the
# above parameters.
#sensor_type: EPCOS 100K B57560G104F
#sensor_pin: analog13
# See the "heater" section for details about the sensor_type and
# sensor_pin parameters.
#min_temp: 0
#max_temp: 100
# The maximum range of valid temperatures (in Celsius) that the
# sensor must remain within. This controls a safety feature
# implemented in the micro-controller code - should the measured
# temperature ever fall outside this range then the micro-controller
# will go into a shutdown state. Set this range just wide enough so
# that reasonable temperatures do not result in an error. These
# parameters must be provided.
#sensor_type:
#sensor_pin:
#control:
#pid_Kp:
#pid_Ki:
#pid_Kd:
#pid_deriv_time:
#pid_integral_max:
#max_delta:
#min_temp:
#max_temp:
# See the "extruder" section in example.cfg for a description of the
# above parameters.
#target_temp: 40.0
# A temperature (in Celsius) that will be the target temperature.
# The default is 40 degrees.
@ -1294,25 +1294,6 @@
# The minimum fan speed (expressed as a value from 0.0 to 1.0) that
# the fan will be set to for PID temperature fans.
# The default is 0.3.
#control: watermark
# Control algorithm (either watermark or pid). This parameter must
# be provided.
#pid_Kp: 40
# Kp is the "proportional" constant for the pid. This parameter must
# be provided for PID temperature fans.
#pid_Ki: 0.2
# Ki is the "integral" constant for the pid. This parameter must be
# provided for PID temperature fans.
#pid_Kd: 0.1
# Kd is the "derivative" constant for the pid. This parameter must
# be provided for PID temperature fans.
#pid_deriv_time: 2.0
# A time value (in seconds) over which the derivative in the pid
# will be smoothed to reduce the impact of measurement noise. The
# default is 2 seconds.
#pid_integral_max:
# The maximum "windup" the integral term may accumulate. The default
# is to use the same value as max_power.
#gcode_id:
# If set, the temperature will be reported in M105 queries using the
# given id. The default is to not report the temperature via M105.