mirror of https://github.com/Desuuuu/klipper.git
mcu: Contact and identify all the mcus prior to configuring them
Break up the connect phase into two phases - mcu_identify and connect. The first phase will contact all the micro-controllers and obtain the "identify" data dictionaries for them. Once all the micro-controllers have been contacted, then they can be configured. This fixes an issue with FIRMWARE_RESTART not working correctly on multi-mcu setups that use restart_method=command. Signed-off-by: Kevin O'Connor <kevin@koconnor.net>
This commit is contained in:
parent
0b90337d59
commit
5eb5841eaf
|
@ -132,6 +132,7 @@ class Printer:
|
|||
def _connect(self, eventtime):
|
||||
try:
|
||||
self._read_config()
|
||||
self.send_event("klippy:mcu_identify")
|
||||
for cb in self.event_handlers.get("klippy:connect", []):
|
||||
if self.state_message is not message_startup:
|
||||
return
|
||||
|
|
|
@ -456,6 +456,8 @@ class MCU:
|
|||
if self._name.startswith('mcu '):
|
||||
self._name = self._name[4:]
|
||||
self._printer.register_event_handler("klippy:connect", self._connect)
|
||||
self._printer.register_event_handler("klippy:mcu_identify",
|
||||
self._mcu_identify)
|
||||
self._printer.register_event_handler("klippy:shutdown", self._shutdown)
|
||||
self._printer.register_event_handler("klippy:disconnect",
|
||||
self._disconnect)
|
||||
|
@ -490,7 +492,6 @@ class MCU:
|
|||
ffi_main, self._ffi_lib = chelper.get_ffi()
|
||||
self._max_stepper_error = config.getfloat(
|
||||
'max_stepper_error', 0.000025, minval=0.)
|
||||
self._move_count = 0
|
||||
self._stepqueues = []
|
||||
self._steppersync = None
|
||||
# Stats
|
||||
|
@ -603,7 +604,16 @@ class MCU:
|
|||
raise error("Can not update MCU '%s' config as it is shutdown" % (
|
||||
self._name,))
|
||||
return config_params
|
||||
def _check_config(self):
|
||||
def _log_info(self):
|
||||
msgparser = self._serial.get_msgparser()
|
||||
log_info = [
|
||||
"Loaded MCU '%s' %d commands (%s / %s)" % (
|
||||
self._name, len(msgparser.messages_by_id),
|
||||
msgparser.version, msgparser.build_versions),
|
||||
"MCU '%s' config: %s" % (self._name, " ".join(
|
||||
["%s=%s" % (k, v) for k, v in self.get_constants().items()]))]
|
||||
return "\n".join(log_info)
|
||||
def _connect(self):
|
||||
config_params = self._send_get_config()
|
||||
if not config_params['is_config']:
|
||||
if self._restart_method == 'rpi_usb':
|
||||
|
@ -622,13 +632,18 @@ class MCU:
|
|||
# Already configured - send init commands
|
||||
self._send_config(config_params['crc'])
|
||||
# Setup steppersync with the move_count returned by get_config
|
||||
self._move_count = config_params['move_count']
|
||||
move_count = config_params['move_count']
|
||||
self._steppersync = self._ffi_lib.steppersync_alloc(
|
||||
self._serial.serialqueue, self._stepqueues, len(self._stepqueues),
|
||||
self._move_count)
|
||||
move_count)
|
||||
self._ffi_lib.steppersync_set_time(
|
||||
self._steppersync, 0., self._mcu_freq)
|
||||
def _connect(self):
|
||||
# Log config information
|
||||
move_msg = "Configured MCU '%s' (%d moves)" % (self._name, move_count)
|
||||
logging.info(move_msg)
|
||||
log_info = self._log_info() + "\n" + move_msg
|
||||
self._printer.set_rollover_info(self._name, log_info, log=False)
|
||||
def _mcu_identify(self):
|
||||
if self.is_fileoutput():
|
||||
self._connect_file()
|
||||
else:
|
||||
|
@ -641,17 +656,9 @@ class MCU:
|
|||
self._clocksync.connect(self._serial)
|
||||
except serialhdl.error as e:
|
||||
raise error(str(e))
|
||||
msgparser = self._serial.get_msgparser()
|
||||
name = self._name
|
||||
log_info = [
|
||||
"Loaded MCU '%s' %d commands (%s / %s)" % (
|
||||
name, len(msgparser.messages_by_id),
|
||||
msgparser.version, msgparser.build_versions),
|
||||
"MCU '%s' config: %s" % (name, " ".join(
|
||||
["%s=%s" % (k, v) for k, v in self.get_constants().items()]))]
|
||||
logging.info("\n".join(log_info))
|
||||
logging.info(self._log_info())
|
||||
ppins = self._printer.lookup_object('pins')
|
||||
pin_resolver = ppins.get_pin_resolver(name)
|
||||
pin_resolver = ppins.get_pin_resolver(self._name)
|
||||
for cname, value in self.get_constants().items():
|
||||
if cname.startswith("RESERVE_PINS_"):
|
||||
for pin in value.split(','):
|
||||
|
@ -661,6 +668,7 @@ class MCU:
|
|||
self._emergency_stop_cmd = self.lookup_command("emergency_stop")
|
||||
self._reset_cmd = self.try_lookup_command("reset")
|
||||
self._config_reset_cmd = self.try_lookup_command("config_reset")
|
||||
msgparser = self._serial.get_msgparser()
|
||||
if (self._restart_method is None
|
||||
and (self._reset_cmd is not None
|
||||
or self._config_reset_cmd is not None)
|
||||
|
@ -669,11 +677,6 @@ class MCU:
|
|||
self.register_response(self._handle_shutdown, 'shutdown')
|
||||
self.register_response(self._handle_shutdown, 'is_shutdown')
|
||||
self.register_response(self._handle_mcu_stats, 'stats')
|
||||
self._check_config()
|
||||
move_msg = "Configured MCU '%s' (%d moves)" % (name, self._move_count)
|
||||
logging.info(move_msg)
|
||||
log_info.append(move_msg)
|
||||
self._printer.set_rollover_info(name, "\n".join(log_info), log=False)
|
||||
# Config creation helpers
|
||||
def setup_pin(self, pin_type, pin_params):
|
||||
pcs = {'stepper': MCU_stepper, 'endstop': MCU_endstop,
|
||||
|
|
Loading…