docs: Documentation on screws_tilt_calculate MAX_DEVIATION parameter (#5522)

Signed-off-by: Kevin Nguyen <ngynkvn@gmail.com>
This commit is contained in:
Kevin Nguyen 2022-05-23 15:49:59 -04:00 committed by GitHub
parent 19a478de37
commit 3081899883
No known key found for this signature in database
GPG Key ID: 4AEE18F83AFDEB23
1 changed files with 2 additions and 2 deletions

View File

@ -979,7 +979,7 @@ is enabled (also see the
[manual level guide](Manual_Level.md#adjusting-bed-leveling-screws-using-the-bed-probe)). [manual level guide](Manual_Level.md#adjusting-bed-leveling-screws-using-the-bed-probe)).
#### SCREWS_TILT_CALCULATE #### SCREWS_TILT_CALCULATE
`SCREWS_TILT_CALCULATE [DIRECTION=CW|CCW] `SCREWS_TILT_CALCULATE [DIRECTION=CW|CCW] [MAX_DEVIATION=<value>]
[<probe_parameter>=<value>]`: This command will invoke the bed screws [<probe_parameter>=<value>]`: This command will invoke the bed screws
adjustment tool. It will command the nozzle to different locations (as adjustment tool. It will command the nozzle to different locations (as
defined in the config file) probing the z height and calculate the defined in the config file) probing the z height and calculate the
@ -987,7 +987,7 @@ number of knob turns to adjust the bed level. If DIRECTION is
specified, the knob turns will all be in the same direction, clockwise specified, the knob turns will all be in the same direction, clockwise
(CW) or counterclockwise (CCW). See the PROBE command for details on (CW) or counterclockwise (CCW). See the PROBE command for details on
the optional probe parameters. IMPORTANT: You MUST always do a G28 the optional probe parameters. IMPORTANT: You MUST always do a G28
before using this command. before using this command. If MAX_DEVIATION is specified, the command will raise a gcode error if any difference in the screw height relative to the base screw height is greater than the value provided.
### [sdcard_loop] ### [sdcard_loop]