mirror of https://github.com/Desuuuu/klipper.git
gcode_arcs: detect CW / CCW move with renamed G2/G3 command (#5096)
The G2 / G3 command might be renamed using `gcode_macro` + `rename_existing`. This change allow detecting clockwise / anti-clockwise moves when the command gets renamed. Signed-off-by: Nick Douma <n.douma@nekoconeko.nl>
This commit is contained in:
parent
2f1edac922
commit
28b568a6ac
|
@ -20,9 +20,15 @@ class ArcSupport:
|
|||
self.gcode_move = self.printer.load_object(config, 'gcode_move')
|
||||
self.gcode = self.printer.lookup_object('gcode')
|
||||
self.gcode.register_command("G2", self.cmd_G2)
|
||||
self.gcode.register_command("G3", self.cmd_G2)
|
||||
self.gcode.register_command("G3", self.cmd_G3)
|
||||
|
||||
def cmd_G2(self, gcmd):
|
||||
self._cmd_inner(gcmd, True)
|
||||
|
||||
def cmd_G3(self, gcmd):
|
||||
self._cmd_inner(gcmd, False)
|
||||
|
||||
def _cmd_inner(self, gcmd, clockwise):
|
||||
gcodestatus = self.gcode_move.get_status()
|
||||
if not gcodestatus['absolute_coordinates']:
|
||||
raise gcmd.error("G2/G3 does not support relative move mode")
|
||||
|
@ -40,7 +46,6 @@ class ArcSupport:
|
|||
raise gcmd.error("G2/G3 neither I nor J given")
|
||||
asE = gcmd.get_float("E", None)
|
||||
asF = gcmd.get_float("F", None)
|
||||
clockwise = (gcmd.get_command() == 'G2')
|
||||
|
||||
# Build list of linear coordinates to move to
|
||||
coords = self.planArc(currentPos, [asX, asY, asZ], [asI, asJ],
|
||||
|
|
Loading…
Reference in New Issue