diff --git a/docs/Pressure_Advance.md b/docs/Pressure_Advance.md index 3d7731e8..9afee00b 100644 --- a/docs/Pressure_Advance.md +++ b/docs/Pressure_Advance.md @@ -63,7 +63,10 @@ in good quality corners: ![corner-good](img/corner-good.jpg) Typical pressure_advance values are between 0.05 and 0.20 (the high -end usually only with bowden extruders). +end usually only with bowden extruders). If there is no significant +improvement seen after increasing pressure_advance to 0.20, then +pressure advance is unlikely to improve the quality of prints. Return +to a default configuration with pressure_advance disabled. It is not unusual for one corner of the test print to be consistently different than the other three corners. This typically occurs when the