klipper-dgus/docs/BLTouch.md

213 lines
9.8 KiB
Markdown
Raw Normal View History

Connecting BL-Touch
===================
A **warning** before you start: Avoid touching the BL-Touch pin with
your bare fingers, since it is quite sensitive to finger grease. And
if you do touch it, be very gentle, in order to not bend or push
anything.
Hook up the BL-Touch "servo" connector to a `control_pin` according to
the BL-Touch documentation or your MCU documentation. Using the
original wiring, the yellow wire from the triple is the `control_pin`
and the white wire from the pair is the `sensor_pin`. You need to
configure these pins according to your wiring. For example:
```
[bltouch]
sensor_pin: P1.24
control_pin: P1.26
```
If the BL-Touch will be used to home the Z axis then set `endstop_pin:
probe:z_virtual_endstop` in the `[stepper_z]` config section and add a
`[safe_z_home]` config section to raise the z axis, home the xy axes,
move to the center of the bed, and home the z axis. For example:
```
[safe_z_home]
home_xy_position: 100,100 # Change coordinates to the center of your print bed
speed: 50
z_hop: 10 # Move up 10mm
z_hop_speed: 5
```
It's important that the z_hop movement in safe_z_home is high enough
that the probe doesn't hit anything even if the probe pin happens to
be in its lowest state.
Initial tests
=============
Before moving on, verify that the BL-Touch is mounted at the correct
height, the pin should be roughly 2 mm above the nozzle when retracted
When you turn on the printer, the BL-Touch probe should perform a
self-test and move the pin up and down a couple of times. Once the
self-test is completed, the pin should be retracted and the red LED on
the probe should be lit. If there are any errors, for example the
probe is flashing red or the pin is down instead of up, please turn
off the printer and check the wiring and configuration.
If the above is looking good, it's time to test that the probe
responds to commands from the firmware. First run `BLTOUCH_DEBUG
COMMAND=pin_down` in your printer terminal. Verify that the pin moves
down, and that the red LED on the probe turns off. If not, check your
wiring and configuration again. Next issue a `BLTOUCH_DEBUG
COMMAND=pin_up`, verify that the pin moves up, and that the red light
turns on again. If it's flashing then there's some problem.
The next step is to confirm that the sensor pin is working correctly.
Run `BLTOUCH_DEBUG COMMAND=pin_down`, verify that the pin moves down,
run `BLTOUCH_DEBUG COMMAND=touch_mode`, run `QUERY_PROBE`, and verify
that command reports "probe: open". Then while gently pushing the pin
up slightly with the nail of your finger run `QUERY_PROBE` again.
Verify the command reports "probe: TRIGGERED". If either query does
not report the correct message then check your wiring and
configuration again. At the completion of this test run `BLTOUCH_DEBUG
COMMAND=pin_up` and verify that the pin moves up.
After completing the BL-Touch command and sensor tests, it is now time
to test homing, but with a twist. Instead of letting the probe pin
touch the print bed, let it touch the nail on your finger. Position
the head far from the bed, issue a `G28`, wait until it starts to move
down, and stop the movement by very gently touching the pin with your
nail. You probably have to do it twice, since the default
configuration makes it probe twice. But be prepared to turn off the
printer, to avoid damage, if it doesn't stop when you touch the pin.
If that was successful, do another `G28` but this time let it touch
the bed as it should.
BL-Touch gone bad
=================
Once the BL-Touch is in inconsistent state, it starts blinking red.
You can force it to leave that state by issuing:
BLTOUCH_DEBUG COMMAND=reset
This may happen if its calibration is interrupted by the probe being
blocked from being extracted.
However, the BL-Touch may also not be able to calibrate itself
anymore. This happens if the screw on its top is in the wrong position
or the magnetic core inside the probe pin has moved. If it has moved
up so that it sticks to the screw, it may not be able to lower its pin
anymore. With this behavior you need to open the screw and use a
ball-point pen to push it gently back into place. Re-Insert the pin
into the BL-Touch so that it falls into the extracted position.
Carefully readjust the headless screw into place. You need to find the
right position so it is able to lower and raise the pin and the red
light turns on and of. Use the `reset`, `pin_up` and `pin_down`
commands to achieve this.
BL-Touch "clones"
=================
Many BL-Touch "clone" devices work correctly with Klipper using the
default configuration. However, some "clone" devices may require
configuration of `pin_up_reports_not_triggered` or
`pin_up_touch_mode_reports_triggered`.
Important! Do not configure `pin_up_reports_not_triggered` or
`pin_up_touch_mode_reports_triggered` to False without first following
these directions. Do not configure either of these to False on a
genuine BL-Touch. Incorrectly setting these to False can increase
probing time and can increase the risk of damaging the printer.
Some "clone" devices are unable to perform Klipper's internal sensor
verification test. On these devices, attempts to home or probe can
result in Klipper reporting a "BLTouch failed to verify sensor state"
error. If this occurs, then manually run the steps to confirm the
sensor pin is working as described in the
[initial tests section](#initial-tests). If the `QUERY_PROBE` commands
in that test always produce the expected results and "BLTouch failed
to verify sensor state" errors still occur, then it may be necessary
to set `pin_up_touch_mode_reports_triggered` to False in the Klipper
config file.
A rare number of old "clone" devices are unable to report when they
have successfully raised their probe. On these devices Klipper will
report a "BLTouch failed to raise probe" error after every home or
probe attempt. One can test for these devices - move the head far from
the bed, run `BLTOUCH_DEBUG COMMAND=pin_down`, verify the pin has
moved down, run `QUERY_PROBE`, verify that command reports "probe:
open", run `BLTOUCH_DEBUG COMMAND=pin_up`, verify the pin has moved
up, and run `QUERY_PROBE`. If the pin remains up, the device does not
enter an error state, and the first query reports "probe: open" while
the second query reports "probe: TRIGGERED" then it indicates that
`pin_up_reports_not_triggered` should be set to False in the Klipper
config file.
Calibrating the BL-Touch offsets
================================
Follow the directions in the [Probe Calibrate](Probe_Calibrate.md)
guide to set the x_offset, y_offset, and z_offset config parameters.
It's a good idea to verify that the Z offset is close to 1mm. If not,
then you probably want to move the probe up or down to fix this. You
want it to trigger well before the nozzle hits the bed, so that
possible stuck filament or a warped bed doesn't affect any probing
action. But at the same time, you want the retracted position to be as
far above the nozzle as possible to avoid it touching printed parts.
If an adjustment is made to the probe position, then rerun the probe
calibration steps.
BL-Touch output mode
====================
* A BL-Touch V3.0 supports setting a 5V or OPEN-DRAIN output mode,
a BL-Touch V3.1 supports this too, but can also store this in its
internal EEPROM. If your controller board needs the fixed 5V high
logic level of the 5V mode you may set the 'set_output_mode'
parameter in the [bltouch] section of the printer config file to
"5V".
*** Only use the 5V mode if your controller boards input line is
5V tolerant. This is why the default configuration of these BL-Touch
versions is OPEN-DRAIN mode. You could potentially damage your
controller boards CPU ***
So therefore:
If a controller board NEEDs 5V mode AND it is 5V tolerant on its
input signal line AND if
- you have a BL-Touch Smart V3.0, you need the use 'set_output_mode: 5V'
parameter to ensure this setting at each startup, since the probe
cannot remember the needed setting.
- you have a BL-Touch Smart V3.1, you have the choice of using
'set_output_mode: 5V' or storing the mode once by use of a
'BLTOUCH_STORE MODE=5V' command manually and NOT using the parameter
'set_output_mode:'.
- you have some other probe: Some probes have a trace on the circuit board
to cut or a jumper to set in order to (permanently) set the output mode.
In that case, omit the 'set_output_mode' parameter completely.
If you have a V3.1, do not automate or repeat storing the output mode to
avoid wearing out the EEPROM of the probe.The BLTouch EEPROM is good for
about 100.000 updates. 100 stores per day would add up to about 3 years
of operation prior to wearing it out. Thus, storing the output mode in a
V3.1 is designed by the vendor to be a complicated operation (the factory
default being a safe OPEN DRAIN mode) and is not suited to be repeatedly
issued by any slicer, macro or anything else, it is preferably only to be
used when first integrating the probe into a printers electronics.
Troubleshooting
===============
* A BL-Touch v3 may not work correctly when its signal wire is
connected to the Z end-stop pin on some printer boards. The symptoms
of this problem are: the BL-Touch probe deploys, the printer
descends, the probe contacts a surface, the BL-Touch raises the
probe, the BL-Touch does not successfully notify the
micro-controller, and the printer continues to descend. The Z
end-stop pin on some printer boards have a capacitor to filter the
signal which the BL-Touch v3 may not support. The simplest solution
is to connect the BL-Touch v3 sensor wire to an available pin on the
printer board that is not associated with an end-stop (and thus is
unlikely to have a capacitor). An alternative solution is to
physically alter the printer board to disable the given end-stop
capacitor or to add a hardware "pull up resistor" to the BL-Touch v3
sensor wire.