2018-08-18 03:16:45 +02:00
|
|
|
# TMC2208 UART communication and configuration
|
|
|
|
#
|
2019-06-06 02:06:05 +02:00
|
|
|
# Copyright (C) 2018-2019 Kevin O'Connor <kevin@koconnor.net>
|
2018-08-18 03:16:45 +02:00
|
|
|
#
|
|
|
|
# This file may be distributed under the terms of the GNU GPLv3 license.
|
2019-02-03 23:32:39 +01:00
|
|
|
import logging, collections
|
2019-02-03 01:46:27 +01:00
|
|
|
import tmc2130
|
2018-08-18 03:16:45 +02:00
|
|
|
|
|
|
|
TMC_FREQUENCY=12000000.
|
|
|
|
|
|
|
|
Registers = {
|
|
|
|
"GCONF": 0x00, "GSTAT": 0x01, "IFCNT": 0x02, "SLAVECONF": 0x03,
|
|
|
|
"OTP_PROG": 0x04, "OTP_READ": 0x05, "IOIN": 0x06, "FACTORY_CONF": 0x07,
|
|
|
|
"IHOLD_IRUN": 0x10, "TPOWERDOWN": 0x11, "TSTEP": 0x12, "TPWMTHRS": 0x13,
|
|
|
|
"VACTUAL": 0x22, "MSCNT": 0x6a, "MSCURACT": 0x6b, "CHOPCONF": 0x6c,
|
|
|
|
"DRV_STATUS": 0x6f, "PWMCONF": 0x70, "PWM_SCALE": 0x71, "PWM_AUTO": 0x72
|
|
|
|
}
|
|
|
|
|
|
|
|
ReadRegisters = [
|
|
|
|
"GCONF", "GSTAT", "IFCNT", "OTP_READ", "IOIN", "FACTORY_CONF", "TSTEP",
|
|
|
|
"MSCNT", "MSCURACT", "CHOPCONF", "DRV_STATUS",
|
|
|
|
"PWMCONF", "PWM_SCALE", "PWM_AUTO"
|
|
|
|
]
|
|
|
|
|
2019-02-03 01:46:27 +01:00
|
|
|
Fields = {}
|
|
|
|
|
|
|
|
Fields["GCONF"] = {
|
|
|
|
"I_scale_analog": 0x01,
|
|
|
|
"internal_Rsense": 0x01 << 1,
|
|
|
|
"en_spreadCycle": 0x01 << 2,
|
|
|
|
"shaft": 0x01 << 3,
|
|
|
|
"index_otpw": 0x01 << 4,
|
|
|
|
"index_step": 0x01 << 5,
|
|
|
|
"pdn_disable": 0x01 << 6,
|
|
|
|
"mstep_reg_select": 0x01 << 7,
|
|
|
|
"multistep_filt": 0x01 << 8,
|
|
|
|
"test_mode": 0x01 << 9
|
|
|
|
}
|
|
|
|
Fields["GSTAT"] = {
|
|
|
|
"reset": 0x01,
|
|
|
|
"drv_err": 0x01 << 1,
|
|
|
|
"uv_cp": 0x01 << 2
|
|
|
|
}
|
|
|
|
Fields["IFCNT"] = {
|
|
|
|
"IFCNT": 0xff
|
|
|
|
}
|
|
|
|
Fields["SLAVECONF"] = {
|
|
|
|
"SENDDELAY": 0x0f << 8
|
|
|
|
}
|
|
|
|
Fields["OTP_PROG"] = {
|
|
|
|
"OTPBIT": 0x07,
|
|
|
|
"OTPBYTE": 0x03 << 4,
|
|
|
|
"OTPMAGIC": 0xff << 8
|
|
|
|
}
|
|
|
|
Fields["OTP_READ"] = {
|
|
|
|
"OTP_FCLKTRIM": 0x1f,
|
|
|
|
"otp_OTTRIM": 0x01 << 5,
|
|
|
|
"otp_internalRsense": 0x01 << 6,
|
|
|
|
"otp_TBL": 0x01 << 7,
|
|
|
|
"OTP_PWM_GRAD": 0x0f << 8,
|
|
|
|
"otp_pwm_autograd": 0x01 << 12,
|
|
|
|
"OTP_TPWMTHRS": 0x07 << 13,
|
|
|
|
"otp_PWM_OFS": 0x01 << 16,
|
|
|
|
"otp_PWM_REG": 0x01 << 17,
|
|
|
|
"otp_PWM_FREQ": 0x01 << 18,
|
|
|
|
"OTP_IHOLDDELAY": 0x03 << 19,
|
|
|
|
"OTP_IHOLD": 0x03 << 21,
|
|
|
|
"otp_en_spreadCycle": 0x01 << 23
|
|
|
|
}
|
|
|
|
# IOIN mapping depends on the driver type (SEL_A field)
|
|
|
|
# TMC222x (SEL_A == 0)
|
|
|
|
Fields["IOIN@TMC222x"] = {
|
|
|
|
"PDN_UART": 0x01 << 1,
|
|
|
|
"SPREAD": 0x01 << 2,
|
|
|
|
"DIR": 0x01 << 3,
|
|
|
|
"ENN": 0x01 << 4,
|
|
|
|
"STEP": 0x01 << 5,
|
|
|
|
"MS1": 0x01 << 6,
|
|
|
|
"MS2": 0x01 << 7,
|
|
|
|
"SEL_A": 0x01 << 8,
|
|
|
|
"VERSION": 0xff << 24
|
|
|
|
}
|
|
|
|
# TMC220x (SEL_A == 1)
|
|
|
|
Fields["IOIN@TMC220x"] = {
|
|
|
|
"ENN": 0x01,
|
|
|
|
"MS1": 0x01 << 2,
|
|
|
|
"MS2": 0x01 << 3,
|
|
|
|
"DIAG": 0x01 << 4,
|
|
|
|
"PDN_UART": 0x01 << 6,
|
|
|
|
"STEP": 0x01 << 7,
|
|
|
|
"SEL_A": 0x01 << 8,
|
|
|
|
"DIR": 0x01 << 9,
|
|
|
|
"VERSION": 0xff << 24,
|
|
|
|
}
|
|
|
|
Fields["FACTORY_CONF"] = {
|
|
|
|
"FCLKTRIM": 0x1f,
|
|
|
|
"OTTRIM": 0x03 << 8
|
|
|
|
}
|
|
|
|
Fields["IHOLD_IRUN"] = {
|
|
|
|
"IHOLD": 0x1f,
|
|
|
|
"IRUN": 0x1f << 8,
|
|
|
|
"IHOLDDELAY": 0x0f << 16
|
|
|
|
}
|
|
|
|
Fields["TPOWERDOWN"] = {
|
|
|
|
"TPOWERDOWN": 0xff
|
|
|
|
}
|
|
|
|
Fields["TSTEP"] = {
|
|
|
|
"TSTEP": 0xfffff
|
|
|
|
}
|
|
|
|
Fields["TPWMTHRS"] = {
|
|
|
|
"TPWMTHRS": 0xfffff
|
|
|
|
}
|
|
|
|
Fields["VACTUAL"] = {
|
|
|
|
"VACTUAL": 0xffffff
|
|
|
|
}
|
|
|
|
Fields["MSCNT"] = {
|
|
|
|
"MSCNT": 0x3ff
|
|
|
|
}
|
|
|
|
Fields["MSCURACT"] = {
|
|
|
|
"CUR_A": 0x1ff,
|
|
|
|
"CUR_B": 0x1ff << 16
|
|
|
|
}
|
|
|
|
Fields["CHOPCONF"] = {
|
|
|
|
"toff": 0x0f,
|
|
|
|
"hstrt": 0x07 << 4,
|
|
|
|
"hend": 0x0f << 7,
|
|
|
|
"TBL": 0x03 << 15,
|
|
|
|
"vsense": 0x01 << 17,
|
|
|
|
"MRES": 0x0f << 24,
|
|
|
|
"intpol": 0x01 << 28,
|
|
|
|
"dedge": 0x01 << 29,
|
|
|
|
"diss2g": 0x01 << 30,
|
|
|
|
"diss2vs": 0x01 << 31
|
|
|
|
}
|
|
|
|
Fields["DRV_STATUS"] = {
|
|
|
|
"otpw": 0x01,
|
|
|
|
"ot": 0x01 << 1,
|
|
|
|
"s2ga": 0x01 << 2,
|
|
|
|
"s2gb": 0x01 << 3,
|
|
|
|
"s2vsa": 0x01 << 4,
|
|
|
|
"s2vsb": 0x01 << 5,
|
|
|
|
"ola": 0x01 << 6,
|
|
|
|
"olb": 0x01 << 7,
|
|
|
|
"t120": 0x01 << 8,
|
|
|
|
"t143": 0x01 << 9,
|
|
|
|
"t150": 0x01 << 10,
|
|
|
|
"t157": 0x01 << 11,
|
|
|
|
"CS_ACTUAL": 0x1f << 16,
|
|
|
|
"stealth": 0x01 << 30,
|
|
|
|
"stst": 0x01 << 31
|
|
|
|
}
|
|
|
|
Fields["PWMCONF"] = {
|
|
|
|
"PWM_OFS": 0xff,
|
|
|
|
"PWM_GRAD": 0xff << 8,
|
|
|
|
"pwm_freq": 0x03 << 16,
|
|
|
|
"pwm_autoscale": 0x01 << 18,
|
|
|
|
"pwm_autograd": 0x01 << 19,
|
|
|
|
"freewheel": 0x03 << 20,
|
|
|
|
"PWM_REG": 0xf << 24,
|
|
|
|
"PWM_LIM": 0xf << 28
|
|
|
|
}
|
|
|
|
Fields["PWM_SCALE"] = {
|
|
|
|
"PWM_SCALE_SUM": 0xff,
|
|
|
|
"PWM_SCALE_AUTO": 0x1ff << 16
|
|
|
|
}
|
|
|
|
Fields["PWM_AUTO"] = {
|
|
|
|
"PWM_OFS_AUTO": 0xff,
|
|
|
|
"PWM_GRAD_AUTO": 0xff << 16
|
|
|
|
}
|
2018-08-18 03:16:45 +02:00
|
|
|
|
2019-05-29 15:14:21 +02:00
|
|
|
SignedFields = ["CUR_A", "CUR_B", "PWM_SCALE_AUTO"]
|
|
|
|
|
2019-02-21 17:35:58 +01:00
|
|
|
FieldFormatters = dict(tmc2130.FieldFormatters)
|
|
|
|
FieldFormatters.update({
|
2019-02-03 08:49:03 +01:00
|
|
|
"SEL_A": (lambda v: "%d(%s)" % (v, ["TMC222x", "TMC220x"][v])),
|
|
|
|
"s2vsa": (lambda v: "1(LowSideShort_A!)" if v else ""),
|
|
|
|
"s2vsb": (lambda v: "1(LowSideShort_B!)" if v else ""),
|
2019-02-21 17:35:58 +01:00
|
|
|
})
|
2019-02-03 08:49:03 +01:00
|
|
|
|
|
|
|
|
2018-08-18 03:16:45 +02:00
|
|
|
######################################################################
|
2019-06-06 02:06:05 +02:00
|
|
|
# TMC2208 uart communication
|
2018-08-18 03:16:45 +02:00
|
|
|
######################################################################
|
|
|
|
|
2019-06-06 02:06:05 +02:00
|
|
|
# Helper code for communicating via TMC uart
|
|
|
|
class MCU_TMC_uart:
|
|
|
|
def __init__(self, config, name_to_reg, fields):
|
2018-08-18 03:16:45 +02:00
|
|
|
self.printer = config.get_printer()
|
2019-02-09 02:11:05 +01:00
|
|
|
self.name = config.get_name().split()[-1]
|
2019-06-06 02:06:05 +02:00
|
|
|
self.name_to_reg = name_to_reg
|
|
|
|
self.fields = fields
|
|
|
|
self.ifcnt = None
|
2018-08-18 03:16:45 +02:00
|
|
|
# pin setup
|
|
|
|
ppins = self.printer.lookup_object("pins")
|
|
|
|
rx_pin_params = ppins.lookup_pin(
|
|
|
|
config.get('uart_pin'), can_pullup=True)
|
|
|
|
tx_pin_desc = config.get('tx_pin', None)
|
|
|
|
if tx_pin_desc is None:
|
|
|
|
tx_pin_params = rx_pin_params
|
|
|
|
else:
|
|
|
|
tx_pin_params = ppins.lookup_pin(tx_pin_desc)
|
|
|
|
if rx_pin_params['chip'] is not tx_pin_params['chip']:
|
2018-12-27 08:38:09 +01:00
|
|
|
raise ppins.error("TMC2208 rx and tx pins must be on the same mcu")
|
2018-08-18 03:16:45 +02:00
|
|
|
self.mcu = rx_pin_params['chip']
|
|
|
|
self.pullup = rx_pin_params['pullup']
|
|
|
|
self.rx_pin = rx_pin_params['pin']
|
|
|
|
self.tx_pin = tx_pin_params['pin']
|
|
|
|
self.oid = self.mcu.create_oid()
|
|
|
|
self.tmcuart_send_cmd = None
|
2018-09-03 17:48:22 +02:00
|
|
|
self.mcu.register_config_callback(self.build_config)
|
2019-06-06 02:06:05 +02:00
|
|
|
def build_config(self):
|
|
|
|
bit_ticks = int(self.mcu.get_adjusted_freq() / 9000.)
|
|
|
|
self.mcu.add_config_cmd(
|
|
|
|
"config_tmcuart oid=%d rx_pin=%s pull_up=%d tx_pin=%s bit_time=%d"
|
|
|
|
% (self.oid, self.rx_pin, self.pullup, self.tx_pin, bit_ticks))
|
|
|
|
cmd_queue = self.mcu.alloc_command_queue()
|
|
|
|
self.tmcuart_send_cmd = self.mcu.lookup_command(
|
|
|
|
"tmcuart_send oid=%c write=%*s read=%c", cq=cmd_queue)
|
|
|
|
def get_fields(self):
|
|
|
|
return self.fields
|
|
|
|
def _calc_crc8(self, data):
|
|
|
|
# Generate a CRC8-ATM value for a bytearray
|
|
|
|
crc = 0
|
|
|
|
for b in data:
|
|
|
|
for i in range(8):
|
|
|
|
if (crc >> 7) ^ (b & 0x01):
|
|
|
|
crc = (crc << 1) ^ 0x07
|
|
|
|
else:
|
|
|
|
crc = (crc << 1)
|
|
|
|
crc &= 0xff
|
|
|
|
b >>= 1
|
|
|
|
return crc
|
|
|
|
def _add_serial_bits(self, data):
|
|
|
|
# Add serial start and stop bits to a message in a bytearray
|
|
|
|
out = 0
|
|
|
|
pos = 0
|
|
|
|
for d in data:
|
|
|
|
b = (d << 1) | 0x200
|
|
|
|
out |= (b << pos)
|
|
|
|
pos += 10
|
|
|
|
res = bytearray()
|
|
|
|
for i in range((pos+7)//8):
|
|
|
|
res.append((out >> (i*8)) & 0xff)
|
|
|
|
return res
|
|
|
|
def _encode_read(self, sync, addr, reg):
|
|
|
|
# Generate a tmc2208 read register message
|
|
|
|
msg = bytearray([sync, addr, reg])
|
|
|
|
msg.append(self._calc_crc8(msg))
|
|
|
|
return self._add_serial_bits(msg)
|
|
|
|
def _encode_write(self, sync, addr, reg, val):
|
|
|
|
# Generate a tmc2208 write register message
|
|
|
|
msg = bytearray([sync, addr, reg, (val >> 24) & 0xff,
|
|
|
|
(val >> 16) & 0xff, (val >> 8) & 0xff, val & 0xff])
|
|
|
|
msg.append(self._calc_crc8(msg))
|
|
|
|
return self._add_serial_bits(msg)
|
|
|
|
def _decode_read(self, reg, data):
|
|
|
|
# Extract a tmc2208 read response message
|
|
|
|
if len(data) != 10:
|
|
|
|
return None
|
|
|
|
# Convert data into a long integer for easy manipulation
|
|
|
|
mval = pos = 0
|
|
|
|
for d in bytearray(data):
|
|
|
|
mval |= d << pos
|
|
|
|
pos += 8
|
|
|
|
# Extract register value
|
|
|
|
val = ((((mval >> 31) & 0xff) << 24) | (((mval >> 41) & 0xff) << 16)
|
|
|
|
| (((mval >> 51) & 0xff) << 8) | ((mval >> 61) & 0xff))
|
|
|
|
# Verify start/stop bits and crc
|
|
|
|
encoded_data = self._encode_write(0x05, 0xff, reg, val)
|
|
|
|
if data != encoded_data:
|
|
|
|
return None
|
|
|
|
return val
|
|
|
|
def get_register(self, reg_name):
|
|
|
|
reg = self.name_to_reg[reg_name]
|
|
|
|
msg = self._encode_read(0xf5, 0x00, reg)
|
|
|
|
if self.printer.get_start_args().get('debugoutput') is not None:
|
|
|
|
return 0
|
|
|
|
for retry in range(5):
|
|
|
|
params = self.tmcuart_send_cmd.send_with_response(
|
|
|
|
[self.oid, msg, 10], 'tmcuart_response', self.oid)
|
|
|
|
val = self._decode_read(reg, params['read'])
|
|
|
|
if val is not None:
|
|
|
|
return val
|
|
|
|
raise self.printer.command_error(
|
|
|
|
"Unable to read tmc2208 '%s' register %s" % (self.name, reg_name))
|
|
|
|
def set_register(self, reg_name, val, print_time=0.):
|
|
|
|
msg = self._encode_write(0xf5, 0x00,
|
|
|
|
self.name_to_reg[reg_name] | 0x80, val)
|
|
|
|
if self.printer.get_start_args().get('debugoutput') is not None:
|
|
|
|
return
|
|
|
|
for retry in range(5):
|
|
|
|
ifcnt = self.ifcnt
|
|
|
|
if ifcnt is None:
|
|
|
|
self.ifcnt = ifcnt = self.get_register("IFCNT")
|
|
|
|
params = self.tmcuart_send_cmd.send_with_response(
|
|
|
|
[self.oid, msg, 0], 'tmcuart_response', self.oid)
|
|
|
|
self.ifcnt = self.get_register("IFCNT")
|
|
|
|
if self.ifcnt == (ifcnt + 1) & 0xff:
|
|
|
|
return
|
|
|
|
raise self.printer.command_error(
|
|
|
|
"Unable to write tmc2208 '%s' register %s" % (self.name, reg_name))
|
|
|
|
|
|
|
|
|
|
|
|
######################################################################
|
|
|
|
# TMC2208 printer object
|
|
|
|
######################################################################
|
|
|
|
|
|
|
|
class TMC2208:
|
|
|
|
def __init__(self, config):
|
|
|
|
self.printer = config.get_printer()
|
|
|
|
self.name = config.get_name().split()[-1]
|
|
|
|
self.printer.register_event_handler("klippy:connect",
|
|
|
|
self._handle_connect)
|
|
|
|
# Setup mcu communication
|
|
|
|
self.regs = collections.OrderedDict()
|
|
|
|
self.fields = tmc2130.FieldHelper(Fields, SignedFields, FieldFormatters,
|
|
|
|
self.regs)
|
|
|
|
self.mcu_tmc = MCU_TMC_uart(config, Registers, self.fields)
|
|
|
|
self.get_register = self.mcu_tmc.get_register
|
|
|
|
self.set_register = self.mcu_tmc.set_register
|
2019-03-01 06:23:19 +01:00
|
|
|
# Add DUMP_TMC, INIT_TMC command
|
2018-08-18 03:16:45 +02:00
|
|
|
gcode = self.printer.lookup_object("gcode")
|
2019-03-23 01:37:03 +01:00
|
|
|
gcode.register_mux_command(
|
|
|
|
"SET_TMC_CURRENT", "STEPPER", self.name,
|
|
|
|
self.cmd_SET_TMC_CURRENT, desc=self.cmd_SET_TMC_CURRENT_help)
|
2018-08-18 03:16:45 +02:00
|
|
|
gcode.register_mux_command(
|
|
|
|
"DUMP_TMC", "STEPPER", self.name,
|
|
|
|
self.cmd_DUMP_TMC, desc=self.cmd_DUMP_TMC_help)
|
2019-03-23 01:37:03 +01:00
|
|
|
gcode.register_mux_command(
|
|
|
|
"SET_TMC_FIELD", "STEPPER", self.name,
|
|
|
|
self.cmd_SET_TMC_FIELD, desc=self.cmd_SET_TMC_FIELD_help)
|
2019-03-01 06:23:19 +01:00
|
|
|
gcode.register_mux_command(
|
|
|
|
"INIT_TMC", "STEPPER", self.name,
|
|
|
|
self.cmd_INIT_TMC, desc=self.cmd_INIT_TMC_help)
|
2019-02-03 19:03:44 +01:00
|
|
|
# Setup basic register values
|
2019-02-03 23:15:43 +01:00
|
|
|
self.fields.set_field("pdn_disable", True)
|
|
|
|
self.fields.set_field("mstep_reg_select", True)
|
|
|
|
self.fields.set_field("multistep_filt", True)
|
2019-03-23 01:37:03 +01:00
|
|
|
vsense, irun, ihold, self.sense_resistor = \
|
|
|
|
tmc2130.get_config_current(config)
|
2019-02-03 23:15:43 +01:00
|
|
|
self.fields.set_field("vsense", vsense)
|
|
|
|
self.fields.set_field("IHOLD", ihold)
|
|
|
|
self.fields.set_field("IRUN", irun)
|
2019-02-03 23:32:39 +01:00
|
|
|
mres, en, thresh = tmc2130.get_config_stealthchop(config, TMC_FREQUENCY)
|
|
|
|
self.fields.set_field("MRES", mres)
|
|
|
|
self.fields.set_field("en_spreadCycle", not en)
|
|
|
|
self.fields.set_field("TPWMTHRS", thresh)
|
2019-02-03 19:03:44 +01:00
|
|
|
# Allow other registers to be set from the config
|
2019-02-03 23:15:43 +01:00
|
|
|
set_config_field = self.fields.set_config_field
|
2019-02-03 19:57:18 +01:00
|
|
|
set_config_field(config, "toff", 3)
|
|
|
|
set_config_field(config, "hstrt", 5)
|
|
|
|
set_config_field(config, "hend", 0)
|
2019-03-08 17:25:19 +01:00
|
|
|
set_config_field(config, "TBL", 2)
|
2019-02-03 19:57:18 +01:00
|
|
|
set_config_field(config, "intpol", True, "interpolate")
|
|
|
|
set_config_field(config, "IHOLDDELAY", 8)
|
|
|
|
set_config_field(config, "TPOWERDOWN", 20)
|
|
|
|
set_config_field(config, "PWM_OFS", 36)
|
|
|
|
set_config_field(config, "PWM_GRAD", 14)
|
|
|
|
set_config_field(config, "pwm_freq", 1)
|
|
|
|
set_config_field(config, "pwm_autoscale", True)
|
|
|
|
set_config_field(config, "pwm_autograd", True)
|
|
|
|
set_config_field(config, "PWM_REG", 8)
|
|
|
|
set_config_field(config, "PWM_LIM", 12)
|
2019-03-01 06:23:19 +01:00
|
|
|
def _init_registers(self):
|
|
|
|
# Send registers
|
2019-02-03 18:22:12 +01:00
|
|
|
for reg_name, val in self.regs.items():
|
2019-01-08 17:09:55 +01:00
|
|
|
self.set_register(reg_name, val)
|
2019-06-06 02:06:05 +02:00
|
|
|
def _handle_connect(self):
|
|
|
|
try:
|
|
|
|
self._init_registers()
|
|
|
|
except self.printer.command_error as e:
|
|
|
|
raise self.printer.config_error(str(e))
|
2018-10-11 01:48:35 +02:00
|
|
|
def get_microsteps(self):
|
2019-02-03 23:15:43 +01:00
|
|
|
return 256 >> self.fields.get_field("MRES")
|
2018-10-11 01:48:35 +02:00
|
|
|
def get_phase(self):
|
2019-02-03 23:15:43 +01:00
|
|
|
mscnt = self.fields.get_field("MSCNT", self.get_register("MSCNT"))
|
|
|
|
return mscnt >> self.fields.get_field("MRES")
|
2019-03-23 01:37:03 +01:00
|
|
|
cmd_SET_TMC_CURRENT_help = "Set the current of a TMC2208 driver"
|
|
|
|
def cmd_SET_TMC_CURRENT(self, params):
|
|
|
|
gcode = self.printer.lookup_object('gcode')
|
|
|
|
vsense = bool(self.fields.get_field("vsense"))
|
|
|
|
if 'HOLDCURRENT' in params:
|
|
|
|
hold_current = gcode.get_float(
|
|
|
|
'HOLDCURRENT', params, above=0., maxval=2.)
|
|
|
|
else:
|
|
|
|
hold_current = tmc2130.bits_to_current(
|
|
|
|
self.fields.get_field("IHOLD"),
|
|
|
|
self.sense_resistor,
|
|
|
|
vsense)
|
|
|
|
if 'CURRENT' in params:
|
|
|
|
run_current = gcode.get_float(
|
|
|
|
'CURRENT', params, minval=hold_current, maxval=2.)
|
|
|
|
else:
|
|
|
|
run_current = tmc2130.bits_to_current(
|
|
|
|
self.fields.get_field("IRUN"),
|
|
|
|
self.sense_resistor,
|
|
|
|
vsense)
|
|
|
|
if 'HOLDCURRENT' in params or 'CURRENT' in params:
|
|
|
|
vsense_calc, irun, ihold = tmc2130.calc_current_config(run_current,
|
|
|
|
hold_current, self.sense_resistor)
|
|
|
|
self.printer.lookup_object('toolhead').wait_moves()
|
|
|
|
if (vsense_calc != vsense):
|
|
|
|
self.fields.set_field("vsense", vsense_calc)
|
|
|
|
self.set_register("CHOPCONF", self.regs["CHOPCONF"])
|
|
|
|
self.fields.set_field("IHOLD", ihold)
|
|
|
|
self.fields.set_field("IRUN", irun)
|
|
|
|
self.set_register("IHOLD_IRUN", self.regs["IHOLD_IRUN"])
|
|
|
|
else:
|
|
|
|
gcode.respond_info(
|
|
|
|
"Run Current: %0.2fA Hold Current: %0.2fA"
|
|
|
|
% (run_current, hold_current))
|
2018-08-18 03:16:45 +02:00
|
|
|
cmd_DUMP_TMC_help = "Read and display TMC stepper driver registers"
|
|
|
|
def cmd_DUMP_TMC(self, params):
|
|
|
|
self.printer.lookup_object('toolhead').get_last_move_time()
|
|
|
|
gcode = self.printer.lookup_object('gcode')
|
|
|
|
logging.info("DUMP_TMC %s", self.name)
|
2019-02-28 00:47:28 +01:00
|
|
|
gcode.respond_info("========== Write-only registers ==========")
|
|
|
|
for reg_name, val in self.regs.items():
|
|
|
|
if reg_name not in ReadRegisters:
|
2019-03-04 19:04:18 +01:00
|
|
|
gcode.respond_info(self.fields.pretty_format(reg_name, val))
|
2019-02-28 00:47:28 +01:00
|
|
|
gcode.respond_info("========== Queried registers ==========")
|
2018-08-18 03:16:45 +02:00
|
|
|
for reg_name in ReadRegisters:
|
2019-06-06 02:06:05 +02:00
|
|
|
val = self.get_register(reg_name)
|
2019-02-03 01:46:27 +01:00
|
|
|
# IOIN has different mappings depending on the driver type
|
|
|
|
# (SEL_A field of IOIN reg)
|
2019-02-03 02:18:59 +01:00
|
|
|
if reg_name == "IOIN":
|
2019-02-03 23:15:43 +01:00
|
|
|
drv_type = self.fields.get_field("SEL_A", val)
|
2019-02-03 01:46:27 +01:00
|
|
|
reg_name = "IOIN@TMC220x" if drv_type else "IOIN@TMC222x"
|
2019-03-04 19:04:18 +01:00
|
|
|
gcode.respond_info(self.fields.pretty_format(reg_name, val))
|
2019-03-01 06:23:19 +01:00
|
|
|
cmd_INIT_TMC_help = "Initialize TMC stepper driver registers"
|
|
|
|
def cmd_INIT_TMC(self, params):
|
|
|
|
logging.info("INIT_TMC 2208 %s", self.name)
|
|
|
|
self.printer.lookup_object('toolhead').wait_moves()
|
|
|
|
self._init_registers()
|
2019-03-23 01:37:03 +01:00
|
|
|
cmd_SET_TMC_FIELD_help = "Set a register field of a TMC2208 driver"
|
|
|
|
def cmd_SET_TMC_FIELD(self, params):
|
|
|
|
gcode = self.printer.lookup_object('gcode')
|
|
|
|
if ('FIELD' not in params or
|
|
|
|
'VALUE' not in params):
|
|
|
|
raise gcode.error("Invalid command format")
|
|
|
|
field = gcode.get_str('FIELD', params)
|
2019-06-02 17:41:15 +02:00
|
|
|
reg = self.fields.field_to_register.get(field)
|
|
|
|
if reg is None:
|
|
|
|
raise gcode.error("Unknown field name '%s'" % field)
|
2019-03-23 01:37:03 +01:00
|
|
|
value = gcode.get_int('VALUE', params)
|
|
|
|
self.fields.set_field(field, value)
|
|
|
|
self.printer.lookup_object('toolhead').wait_moves()
|
|
|
|
self.set_register(reg, self.regs[reg])
|
2018-08-18 03:16:45 +02:00
|
|
|
|
|
|
|
def load_config_prefix(config):
|
|
|
|